Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Sensor Fault Detection and Isolation Based on Artificial Neural Networks and Fuzzy Logic Applicated on Induction Motor for Electrical Vehicle

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 2 (2017) · hlm. 601–611

DOI
10.11591/ijpeds.v8.i2.pp601-611
ISSN
2722-256X, 2088-8694
Terbit
2017-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Recently, research has picked up a fervent pace in the area of fault diagnosis of electrical vehicle. Like failures of a position sensor, a voltage sensor, and current sensors. Three-phase induction motors are the “workhorses” of industry and are the most widely used electrical machines. This paper presents a scheme for Fault Detection and Isolation (FDI). The proposed approach is a sensor-based technique using the mains current measurement. Current sensors are widespread in power converters control and in electrical drives. Thus, to ensure continuous operation with reconfiguration control, a fast sensor fault detection and isolation is required. In this paper, a new and fast faulty current sensor detection and isolation is presented. It is derived from intelligent techniques. The main interest of field programmable gate array is the extremely fast computation capabilities. That allows a fast residual generation when a sensor fault occurs. Using of Xilinx System Generator in Matlab / Simulink allows the real-time simulation and implemented on a field programmable gate array chip without any VHSIC Hardware Description Language coding. The sensor fault detection and isolation algorithm was implemented targeting a Virtex5. Simulation results are given to demonstrate the efficiency of this FDI approach.

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Monastir
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdellatif MtibaaUniversity of Monastir1
Mohamed Faouzi MimouniUniversity of Monastir1
Saber KrimUniversity of Monastir1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Sensor Fault Detection and Isolation Based on Artificial Neural Networks and Fuzzy Logic Applicated on Induction Motor for Electrical Vehicle</dc:title>
	<dc:creator>Boukadida, Souha</dc:creator>
	<dc:creator>Gdaim, Soufien</dc:creator>
	<dc:creator>Mtiba, Abdellatif</dc:creator>
	<dc:description xml:lang="en-US">Recently, research has picked up a fervent pace in the area of fault diagnosis of electrical vehicle. Like failures of a position sensor, a voltage sensor, and current sensors. Three-phase induction motors are the “workhorses” of industry and are the most widely used electrical machines. This paper presents a scheme for Fault Detection and Isolation (FDI). The proposed approach is a sensor-based technique using the mains current measurement. Current sensors are widespread in power converters control and in electrical drives. Thus, to ensure continuous operation with reconfiguration control, a fast sensor fault detection and isolation is required. In this paper, a new and fast faulty current sensor detection and isolation is presented. It is derived from intelligent techniques. The main interest of field programmable gate array is the extremely fast computation capabilities. That allows a fast residual generation when a sensor fault occurs. Using of Xilinx System Generator in Matlab / Simulink allows the real-time simulation and implemented on a field programmable gate array chip without any VHSIC Hardware Description Language coding. The sensor fault detection and isolation algorithm was implemented targeting a Virtex5. Simulation results are given to demonstrate the efficiency of this FDI approach.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2017-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6746</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i2.pp601-611</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 2: June 2017; 601-611</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6746/6383</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Souha Boukadida, Soufien Gdaim, Abdellatif Mtiba</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>