The conventional line-commutated ac-to-dc converters/ inverters have square-shaped line current. It contains higher-order harmonics which generates EMI and it causes more heating of the core of distribution or power transformers. PWM based inverters using MOSFET/IGBT have higher switching losses, and the power handling capability and reliability are quite low in comparison to thyristors/ SCR. A thyristor based forced commutated inverters are not suitable for PWM applications due to the problems of commutation circuits. A pure sinusoidal voltage output or waveform with low harmonic contents is most desirable for ac load using dc to ac conversion. This paper presents a new multilevel inverter topology in which three phase ac- to-dc converter circuits are used in inversion mode by controlling the switching angle. Due to natural commutation, no separate circuit is required for synchronization. In this paper simulation and analysis are done for grid-tied three-phase 6-pulse, Two three-phase, 3-pulse and 12-pulse converter. These converters are analysed for different battery voltage and different switching angle combinations in order to reduce the total harmonic distortion (THD). Three-phase harmonic filters are further added to the grid side to reduce the harmonic content in the line current. A comparative study of these converters is also presented in this paper.

Jaringan kolaborasi para penulis

9 penulis · 15 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Integral University
  • Aligarh Muslim University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Fatima YasmeenIntegral University1
Yusuf Uzzaman KhanAligarh Muslim University1
Mohammed AsimIntegral University1
Mohd TariqAligarh Muslim University1
Imtiaz AshrafAligarh Muslim University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Development of a Novel Three Phase Grid-Tied Multilevel Inverter Topology</dc:title>
	<dc:creator>Shadab, Mirza Mohammad</dc:creator>
	<dc:creator>Mallick, Mohammad Arifuddin</dc:creator>
	<dc:creator>Tufail, Mohammad</dc:creator>
	<dc:creator>Asghar, M. S. Jamil</dc:creator>
	<dc:description xml:lang="en-US">The conventional line-commutated ac-to-dc converters/ inverters have square-shaped line current. It contains higher-order harmonics which generates EMI and it causes more heating of the core of distribution or power transformers. PWM based inverters using MOSFET/IGBT have higher switching losses, and the power handling capability and reliability are quite low in comparison to thyristors/ SCR. A thyristor based forced commutated inverters are not suitable for PWM applications due to the problems of commutation circuits. A pure sinusoidal voltage output or waveform with low harmonic contents is most desirable for ac load using dc to ac conversion. This paper presents a new multilevel inverter topology in which three phase ac- to-dc converter circuits are used in inversion mode by controlling the switching angle. Due to natural commutation, no separate circuit is required for synchronization. In this paper simulation and analysis are done for grid-tied three-phase 6-pulse, Two three-phase, 3-pulse and 12-pulse converter. These converters are analysed for different battery voltage and different switching angle combinations in order to reduce the total harmonic distortion (THD). Three-phase harmonic filters are further added to the grid side to reduce the harmonic content in the line current. A comparative study of these converters is also presented in this paper.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2016-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5263</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v7.i3.pp826-834</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 7, No 3: September 2016; 826-834</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v7.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5263/5484</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Mirza Mohammad Shadab, Mohammad Arifuddin Mallick, Mohammad Tufail, M. S. Jamil Asghar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>