Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance and Energy Saving Analysis of Grid Connected Photovoltaic in West Sumatera

International Journal of Power Electronics and Drive Systems · Vol. 7 No. 4 (2016) · hlm. 1348–1354

DOI
10.11591/ijpeds.v7.i4.pp1348-1354
ISSN
2722-256X, 2088-8694
Terbit
2016-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The paper presents performance and energy saving analysis of 1.25 kWp grid connected Photovoltaic system under difference weather condition in West Sumatera. The measured data were performed during weather data that often occur in West Sumatra i.e. sunny, overcast, raining and cloudy. The synchronizing process successfully done even bad weather conditions when sunlight was low automatically. Photovoltaic in average start producing power from 7:00 AM to 6:00 PM for normal or clear sky, however under overcast, raining and cloudy weather, the PV power decreased and disconnected earlier before sunset. During intermittent raining, overcast and cloud covered the PV power output show an irregular profile. The PV energy saving performed for three residential connection cases: 1300 VA, 900 VA with subsidized and 900 VA without subsidized. The solar PV installation have more benefits and energy saving for 1300 VA, 900 VA without subsidized with payback period around 8.5 years. However, the 900 VA with subsidized take longer 20.8 years, but still in PV lifespan 25 years. In the future, household subsidies may be reduced or eliminated, the solar energy will be viable alternative of energy resources when it can produce electricity at a cost equivalent to utility grid PLN rate.

Jaringan kolaborasi para penulis

17 penulis · 39 tautan kepenulisan bersama · 11 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Universitas Negeri Padang
  • Institut Teknologi Padang
  • Diponegoro University
  • National Institute of Technology Hamirpur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Andi PawawoiAndalas University4
Fajril AkbarAndalas University4
Muhammad Imran HamidAndalas University2
Syafii SyafiiAndalas University2
Krismadinata KrismadinataUniversitas Negeri Padang2
Muhammad Imran HamidAndalas University1
Yudi ArfanAndalas University1
Axel DorizaAndalas University1
Zuriman AnthonyInstitut Teknologi Padang1
Rizka AmaliaDiponegoro University1
Hasmat MalikNational Institute of Technology Hamirpur1
Dendi Adi SaputraAndalas University1
Igo Cikal MuharramAndalas University1
Asnil AsnilAndalas University1
Muhammad NasirAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance and Energy Saving Analysis of Grid Connected Photovoltaic in West Sumatera</dc:title>
	<dc:creator>Ghazali, Syafii</dc:creator>
	<dc:creator>Nazir, Refdinal</dc:creator>
	<dc:description xml:lang="en-US">The paper presents performance and energy saving analysis of 1.25 kWp grid connected Photovoltaic system under difference weather condition in West Sumatera.  The measured data were performed during weather data that often occur in West Sumatra i.e. sunny, overcast, raining and cloudy. The synchronizing process successfully done even bad weather conditions when sunlight was low automatically. Photovoltaic in average start producing power from 7:00 AM to 6:00 PM for normal or clear sky, however under overcast, raining and cloudy weather, the PV power decreased and disconnected earlier before sunset. During intermittent raining, overcast and cloud covered the PV power output show an irregular profile. The PV energy saving performed for three residential connection cases: 1300 VA, 900 VA with subsidized and 900 VA without subsidized. The solar PV installation have more benefits and energy saving for 1300 VA, 900 VA without subsidized with payback period around 8.5 years. However, the 900 VA with subsidized take longer 20.8 years, but still in PV lifespan 25 years. In the future, household subsidies may be reduced or eliminated, the solar energy will be viable alternative of energy resources when it can produce electricity at a cost equivalent to utility grid PLN rate. </dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2016-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5852</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v7.i4.pp1348-1354</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 7, No 4: December 2016; 1348-1354</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v7.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5852/5637</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Syafii Ghazali, Refdinal Nazir</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>