Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Current mode control of single phase grid tie inverter with anti-islanding

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 1 (2021) · hlm. 241–248

DOI
10.11591/ijpeds.v12.i1.pp241-248
ISSN
2722-256X, 2088-8694
Terbit
2021-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The aim of this paper is to explore the use of various current mode control (CMC) techniques to design a single phase grid tie inverter integrated with anti-islanding protection. Three types of CMC techniques have been discussed, namely current hysteresis control (CHC), constant frequency control (CFC) and average current mode control (ACMC). The performance of the grid tie inverter in the event of grid voltage failure is also studied to help install an anti-islanding mechanism. The proposed control techniques shall eliminate the use of Phase locked loop (PLL) control as the current reference is generated from the grid voltage itself. All three current mode control techniques of an inverter have been simulated in MATLAB/Simulink to evaluate the performance of the designed inverter. The simulated results show a current THD of less than 5% in all three methods and a good anti-islanding response.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 15 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jawaharlal Nehru Technological University Anantapur
  • M S Ramaiah University of Applied Sciences
  • Acharya Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ch. Sai BabuJawaharlal Nehru Technological University Anantapur3
D. V. Ashok KumarJawaharlal Nehru Technological University Anantapur3
Shreyas KarnickAfiliasi tidak diketahui1
Madhu PalatiAfiliasi tidak diketahui1
Prakash RAcharya Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Current mode control of single phase grid tie inverter with anti-islanding</dc:title>
	<dc:creator>Lakshminarayanan, Sanjay</dc:creator>
	<dc:creator>B M, Kiran Kumar</dc:creator>
	<dc:creator>Rao, S. Nagaraja</dc:creator>
	<dc:creator>S., Pranupa</dc:creator>
	<dc:subject xml:lang="en-US">Anti-islanding, Average current mode control, Current hysteresis control, Constant frequency control, Phase locked loop, Total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">The aim of this paper is to explore the use of various current mode control (CMC) techniques to design a single phase grid tie inverter integrated with anti-islanding protection. Three types of CMC techniques have been discussed, namely current hysteresis control (CHC), constant frequency control (CFC) and average current mode control (ACMC). The performance of the grid tie inverter in the event of grid voltage failure is also studied to help install an anti-islanding mechanism. The proposed control techniques shall eliminate the use of Phase locked loop (PLL) control as the current reference is generated from the grid voltage itself. All three current mode control techniques of an inverter have been simulated in MATLAB/Simulink to evaluate the performance of the designed inverter. The simulated results show a current THD of less than 5% in all three methods and a good anti-islanding response.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20868</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i1.pp241-248</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 1: March 2021; 241-248</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20868/13343</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Sanjay Lakshminarayanan, Kiran Kumar B M, S. Nagaraja Rao, Pranupa S.</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>