Abstrak

Due to their excellent characteristics; Reaching high voltage inverters by using lower voltage switches, reduced output current distortion, dv/dt, and switching losses decrease, efficiency rise, multilevel inverters are an interesting alternative to the two-level inverters especially in traction applications. Many studies compared both topologies, but this work compare performances of Field oriented control strategy using two levels and neutral point piloted three levels inverter supplied by space pulse width modulation. Based on real parameters, this work shows that this efficient multilevel inverter reduces current distortion and torque ripples in a manner to reduces the size and cost of all railway traction systems chosen for this work

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 53 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Hassan II Casablanca
  • Chouaib Doukkali University
  • Université Ibn Zohr
  • Université Sultan Moulay Slimane
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aziz El AfiaUniversity of Hassan II Casablanca6
Mhammed HasounUniversity of Hassan II Casablanca4
Karim BenkiraneUniversity of Hassan II Casablanca4
Jawad LamterkatiUniversity of Hassan II Casablanca3
Abdelouahed MesbahiUniversity of Hassan II Casablanca2
Ayoub NouaitiUniversity of Hassan II Casablanca2
Lahcen OuboubkerUniversité Ibn Zohr2
Slimane ChiboubUniversity of Hassan II Casablanca1
Souhail BarakatUniversity of Hassan II Casablanca1
Badr N’hiliUniversity of Hassan II Casablanca1
Abdennasser BenkadaChouaib Doukkali University1
Mohamed MonkadeChouaib Doukkali University1
Fouad LabchirUniversity of Hassan II Casablanca1
Driss YousfiUniversiti Malaysia Pahang Al-Sultan Abdullah1
A. SaadAfiliasi tidak diketahui1
F.Z. TahiriAfiliasi tidak diketahui1
Khalid ChikhUniversité Sultan Moulay Slimane1
Abdelilah HassouneUniversity of Hassan II Casablanca1
Tarik BouragbaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Assessment of field oriented induction machine control strategy using new generation of inverters in BB36000 locomotive</dc:title>
	<dc:creator>chaikhy, Hamid</dc:creator>
	<dc:creator>Es-saadi, Mouna</dc:creator>
	<dc:creator>Khafallah, Mohamed</dc:creator>
	<dc:subject xml:lang="en-US">Field oriented control; Neutral point piloted inveter; Railway traction; Space pulse width modulation</dc:subject>
	<dc:description xml:lang="en-US">Due to their excellent characteristics; Reaching high voltage inverters by using lower voltage switches, reduced output current distortion, dv/dt, and switching losses decrease, efficiency rise, multilevel inverters are an interesting alternative to the two-level inverters especially in traction applications. Many studies compared both topologies, but this work compare performances of Field oriented control strategy using two levels and neutral point piloted three levels inverter supplied by space pulse width modulation. Based on real parameters, this work shows that this efficient multilevel inverter reduces current distortion and torque ripples in a manner to reduces the size and cost of all railway traction systems chosen for this work</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21238</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i3.pp1295-1304</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 3: September 2022; 1295-1304</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21238/13946</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Hamid chaikhy, Mouna Es-saadi, Mohamed Khafallah</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>