Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Single Phase Inverter System using Proportional Resonant Current Control

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 4 (2017) · hlm. 1913–1918

DOI
10.11591/ijpeds.v8.i4.pp1913-1918
ISSN
2722-256X, 2088-8694
Terbit
2017-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD).

Jaringan kolaborasi para penulis

17 penulis · 34 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Newcastle University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
M. H. RemlanTun Hussein Onn University of Malaysia2
Glynn J. AtkinsonNewcastle University2
Matthew ArmstrongNewcastle University2
Noor Mazliza Badrul ShamTun Hussein Onn University of Malaysia1
Ronald JacksonTun Hussein Onn University of Malaysia1
Muhammad Shukri AhmadTun Hussein Onn University of Malaysia1
Omar Abu HassanTun Hussein Onn University of Malaysia1
Mohd Shamian ZainalTun Hussein Onn University of Malaysia1
Ahmad Alabqari Ma’radziTun Hussein Onn University of Malaysia1
Tengku Nadzlin Tengku IbrahimTun Hussein Onn University of Malaysia1
A.F.M. NoorTun Hussein Onn University of Malaysia1
Siti Amely JumaatTun Hussein Onn University of Malaysia1
Md Ruhul AminTun Hussein Onn University of Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Single Phase Inverter System using Proportional Resonant Current Control</dc:title>
	<dc:creator>Chen, K.C.</dc:creator>
	<dc:creator>Salimin, S.</dc:creator>
	<dc:creator>Zulkifli, S. A.</dc:creator>
	<dc:creator>Aziz, R.</dc:creator>
	<dc:description xml:lang="en-US">This paper presents the harmonic reduction performance of proportional resonant (PR) current controller in single phase inverter system connected to nonlinear load. In the study, proportional resonant current controller and low pass filter is discussed to eliminate low order harmonics injection in single phase inverter system. The potential of nonlinear load in producing harmonics is showed and identified by developing a nonlinear load model using a full bridge rectifier circuit. The modelling and simulation is done in MATLAB Simulink while harmonic spectrum results are obtained using Fast Fourier Transfor. End result show PR current controller capability to overcome the injection of current harmonic problems thus improved the overall total harmonic distortion (THD).</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2017-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8596</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i4.pp1913-1918</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 4: December 2017; 1913-1918</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8596/7815</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 K.C. Chen, S. Salimin, S. A. Zulkifli, R. Aziz</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>