Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Resonant converter for fast-charging applications

International Journal of Power Electronics and Drive Systems · Vol. 16 No. 3 (2025) · hlm. 1832–1839

DOI
10.11591/ijpeds.v16.i3.pp1832-1839
ISSN
2722-256X, 2088-8694
Terbit
2025-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Resonant converters (RCs) are gaining attention from the research community due to their significant contributions to the architecture of electric vehicle (EV) charging infrastructure. The primary part of RC is responsible for enabling constant-current (CC) charging, which helps lower inrush current, decrease losses, and improve efficiency. While the load current stays constant during charging using the CC approach, the source current grows linearly with charging time. However, pulling a high source current increases the rating of the inverter switches, which stresses them, raises their temperature, increases heat sink demand, and causes conduction loss—all of which are undesirable. Consequently, the rated CC is provided by the P2 topology of RC, which has a lower peak current source than other topologies and will improve charger performance. However, this assertion must be verified by mathematical modeling, design with theoretical calculations, specifications, and MATLAB simulation before execution. By providing a constant load current of 5 A at a DC source voltage of 200 V, the P2 RC and the conventional LCL RC are designed to compare source current values.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 16 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Annamalai University
  • Visvesvaraya Technological University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ujwala GajulaAnnamalai University1
Gouthami EragamreddyVisvesvaraya Technological University1
N. Malla ReddyAfiliasi tidak diketahui1
Veeranjaneyulu GopuVisvesvaraya Technological University1
Naresh PasulaAfiliasi tidak diketahui1
Ezhilarasi ArivukkannuAnnamalai University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Resonant converter for fast-charging applications</dc:title>
	<dc:creator>Kumari, Remala Geshma</dc:creator>
	<dc:creator>Kumari, Narahari Krishna</dc:creator>
	<dc:creator>Shravya, Kankipati</dc:creator>
	<dc:subject xml:lang="en-US">constant-current application; P2 resonant immittance converter; power electronics; resonant converter; voltage-current conversion</dc:subject>
	<dc:description xml:lang="en-US">Resonant converters (RCs) are gaining attention from the research community due to their significant contributions to the architecture of electric vehicle (EV) charging infrastructure. The primary part of RC is responsible for enabling constant-current (CC) charging, which helps lower inrush current, decrease losses, and improve efficiency. While the load current stays constant during charging using the CC approach, the source current grows linearly with charging time. However, pulling a high source current increases the rating of the inverter switches, which stresses them, raises their temperature, increases heat sink demand, and causes conduction loss—all of which are undesirable. Consequently, the rated CC is provided by the P2 topology of RC, which has a lower peak current source than other topologies and will improve charger performance. However, this assertion must be verified by mathematical modeling, design with theoretical calculations, specifications, and MATLAB simulation before execution. By providing a constant load current of 5 A at a DC source voltage of 200 V, the P2 RC and the conventional LCL RC are designed to compare source current values.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23971</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i3.pp1832-1839</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 3: September 2025; 1832-1839</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23971/15026</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Remala Geshma Kumari, Narahari Krishna Kumari, Kankipati Shravya</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>