Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Multiple Inverters Operated in Parallel for Proportional Load Sharing in Microgrid

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 2 (2017) · hlm. 654–666

DOI
10.11591/ijpeds.v8.i2.pp654-666
ISSN
2722-256X, 2088-8694
Terbit
2017-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The new energy source utilization and development, gradual rise of distributed power grid miniaturization, intelligence, control has become a trend. In order to make microgrid reliable and efficiently run, control technology of microgrid has become a top priority and an inverter as microgrid basic unit, its control has become the most important part in microgrid. In this paper, three inverters are operated in parallel using an P-V/Q-F droop control is investigated. Mathematical model of three phase inverter with LC filter is derived, which is based on the voltage and current dual control loop. Parallel control strategy based on P-V/Q-F droop control, does not require a real time communications between the inverters and more suitable for microgrid applications. To verify the feasibility and validity of the droop control scheme, simulation is done in Matlab/Simulink and results indicate droop control has significant effect on power sharing and balancing the voltage magnitude, frequency.

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Manipal Academy of Higher Education
  • National Institute of Technology Karnataka
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
N. S. JayalakshmiManipal Academy of Higher Education1
Sanchit JainManipal Academy of Higher Education1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Multiple Inverters Operated in Parallel for Proportional Load Sharing in Microgrid</dc:title>
	<dc:creator>Raj D, Chethan</dc:creator>
	<dc:creator>Gaonkar, D N</dc:creator>
	<dc:description xml:lang="en-US">The new energy source utilization and development, gradual rise of distributed power grid miniaturization, intelligence, control has become a trend. In order to make microgrid reliable and efficiently run, control technology of microgrid has become a top priority and an inverter as microgrid basic unit, its control has become the most  important part in microgrid. In this paper, three inverters are operated in parallel using an P-V/Q-F droop control is investigated. Mathematical model of three phase inverter with LC filter is derived, which is based on the voltage and current dual control loop. Parallel control strategy based on P-V/Q-F droop control, does not require a real time communications between the inverters and more suitable for microgrid applications. To verify the feasibility and validity of the droop control scheme, simulation is done in Matlab/Simulink and results indicate droop control has significant effect on power sharing and balancing the voltage magnitude, frequency.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2017-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6751</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i2.pp654-666</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 2: June 2017; 654-666</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6751/6388</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Chethan Raj D, D N Gaonkar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>