Analysis of the feasibility of adding a grid-connected hybrid photovoltaic system to reduce electrical load

International Journal of Power Electronics and Drive Systems · Vol. 14 No. 2 (2023) · hlm. 1160–1171

DOI
10.11591/ijpeds.v14.i2.pp1160-1171
ISSN
2722-256X, 2088-8694
Terbit
2023-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The power generation system with hybrid system grid connected (HSGC) technology is an energy-saving technology that is able to compensate for electricity loads in an energy-efficient manner in today's technological advances. Electrical transient analyzer power (ETAP) simulation software is implemented so that the modeling will have an impact on the development of hybrid systems. Testing the reliability of the system is simulated at the load of school buildings, laboratories, mosques, and kindergarten schools. parameters obtained by evaluating the ratio of the voltage drop before and after the addition of photovoltaic. The value of the voltage drops decreases with the integration of hybrid photovoltaic. The school building panels experienced a voltage drop of 0.15%, reduced after the addition of photovoltaics and wind turbines. Then on the Laboratory panel, a voltage drops of 0.05% was obtained, on the mosque panel the voltage drop reached 0.11%, and on the kindergarten building panel the voltage drop reached 0.09% after the addition of photovoltaic hybrid. From this comparison it can be said that PV and wind turbines can affect the voltage drop and reduce the consumption of electricity loads from the grid caused by adding power from the hybrid photovoltaic hybrid to each load.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 126 tautan kepenulisan bersama · 49 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Medan Area University
  • Andalas University
  • Universiti Malaysia Perlis
  • University of Bangka Belitung
  • Universitas Tidar
  • Malikussaleh University
  • Universitas Prima Indonesia
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Indri DayanaMedan Area University14
Dadan RamdanMedan Area University13
Muhammad Fadlan SiregarMedan Area University10
Indri DayanaMedan Area University7
Rahmad B. Y. SyahMedan Area University6
Nukhe Andri SilvianaMedan Area University5
M. IrwantoUniversitas Prima Indonesia5
Siti Utari RahayuNational Chung Hsing University5
Tino HermantoMedan Area University4
Yopan Rahmad AldoriMedan Area University4
Andi PawawoiAndalas University3
Ahmad Zaidi AbdullahUniversiti Malaysia Perlis3
Aulia AuliaAndalas University3
Martha RiannaUniversitas Sumatera Utara3
Arnawan HasibuanMalikussaleh University3
Sapto NisworoUniversitas Tidar3
Wahri SunandaUniversity of Bangka Belitung2
Novizon NovizonAndalas University2
I Made Ari NrarthaUniversity of Mataram2
Refdinal NazirAndalas University2
Fajril AkbarAndalas University2
Azriyenni Azhari ZakriRiau University2
Muhammad Ridha FauziAndalas University2
Imra Nur IzrillahAndalas University2
Mohamad Nur Khairul Hafizi RohaniUniversiti Malaysia Perlis2
N. AzizanUniversiti Malaysia Perlis2
Ricky MaulanaAndalas University2
Syarifah Muthia PutriMedan Area University2
Muhammad Ilhamdi RusydiAndalas University2
N. S. B. JamiliUniversiti Malaysia Perlis1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Samila Mat ZaliUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of the feasibility of adding a grid-connected hybrid photovoltaic system to reduce electrical load</dc:title>
	<dc:creator>Mungkin, Moranain</dc:creator>
	<dc:creator>Satria, Habib</dc:creator>
	<dc:creator>Maizana, Dina</dc:creator>
	<dc:creator>Isa, Muzamir</dc:creator>
	<dc:creator>Syafii, Syafii</dc:creator>
	<dc:creator>Puriza, Muhammad Yonggi</dc:creator>
	<dc:subject xml:lang="en-US">electrical load; hybrid technology; photovoltaic on grid; software ETAP; wind turbine</dc:subject>
	<dc:description xml:lang="en-US">The power generation system with hybrid system grid connected (HSGC) technology is an energy-saving technology that is able to compensate for electricity loads in an energy-efficient manner in today's technological advances. Electrical transient analyzer power (ETAP) simulation software is implemented so that the modeling will have an impact on the development of hybrid systems. Testing the reliability of the system is simulated at the load of school buildings, laboratories, mosques, and kindergarten schools. parameters obtained by evaluating the ratio of the voltage drop before and after the addition of photovoltaic. The value of the voltage drops decreases with the integration of hybrid photovoltaic. The school building panels experienced a voltage drop of 0.15%, reduced after the addition of photovoltaics and wind turbines. Then on the Laboratory panel, a voltage drops of 0.05% was obtained, on the mosque panel the voltage drop reached 0.11%, and on the kindergarten building panel the voltage drop reached 0.09% after the addition of photovoltaic hybrid. From this comparison it can be said that PV and wind turbines can affect the voltage drop and reduce the consumption of electricity loads from the grid caused by adding power from the hybrid photovoltaic hybrid to each load.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Author  thanks  to  Kemenristekdikti for  sponsor  and  financial  support  acknowledgments  with contract  number  122/LL1/K/2022,  1586/LP2M/03.3.1/VI/2022. We also would like to thank Medan Area University for supporting this research.</dc:contributor>
	<dc:date>2023-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22331</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i2.pp1160-1171</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 2: June 2023; 1160-1171</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22331/14189</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Moranain Mungkin, Habib Satria, Dina Maizana, Muzamir Isa, Syafii Syafii, Muhammad Yonggi Puriza</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>