Abstrak
Analysis of bad data in an IEEE 14 bus system with phasor measuring units (PMU) devices is carried out in this paper. The normal operating condition data achieved from the PMU in the bus system is compared to the data achieved during faults in the bus system. A principal component analysis (PCA) technique is proposed in this paper for distinguishing the difference between data transmission during normal and fault conditions. The PCA approach detects the dynamical magnitudes of the measurements taken and also determines the noise caused by the disturbances. The grid system is updated with unified power quality conditioner (UPQC) improvising the parameters of the system to mitigate the fault. The PMU devices use PCA technique for a comparative analysis of the measured components analyzing the performance of the system under different operating conditions. The simulation of these modules is carried out in Simulink environment of MATLAB software with PCA done concerning time.
Jaringan kolaborasi para penulis
14 penulis ·
19 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Koneru Lakshmaiah Education Foundation Deccan College Post Graduate and Research Institute Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Bad data analysis and detection using PMU with UPQC integration to grid during fault conditions</dc:title>
<dc:creator>Kabra, Preeti Nitin</dc:creator>
<dc:creator>Lalitha, Suraparaju Venkata Naga Lakshmi</dc:creator>
<dc:creator>Donepudi, Sudha Rani</dc:creator>
<dc:subject xml:lang="en-US">Bad data detection; MATLAB; Phasor measuring units; Principal component analysis; Unified power quality conditioner</dc:subject>
<dc:description xml:lang="en-US">Analysis of bad data in an IEEE 14 bus system with phasor measuring units (PMU) devices is carried out in this paper. The normal operating condition data achieved from the PMU in the bus system is compared to the data achieved during faults in the bus system. A principal component analysis (PCA) technique is proposed in this paper for distinguishing the difference between data transmission during normal and fault conditions. The PCA approach detects the dynamical magnitudes of the measurements taken and also determines the noise caused by the disturbances. The grid system is updated with unified power quality conditioner (UPQC) improvising the parameters of the system to mitigate the fault. The PMU devices use PCA technique for a comparative analysis of the measured components analyzing the performance of the system under different operating conditions. The simulation of these modules is carried out in Simulink environment of MATLAB software with PCA done concerning time.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2023-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22237</dc:identifier>
<dc:identifier>10.11591/ijpeds.v14.i1.pp256-265</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 1: March 2023; 256-265</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v14.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22237/14079</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Preeti Nitin Kabra, Suraparaju Venkata Naga Lakshmi Lalitha, Sudha Rani Donepudi</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Kabra, P. N., Lalitha, S. V. N. L., & Donepudi, S. R. (2023). Bad data analysis and detection using PMU with UPQC integration to grid during fault conditions. International Journal of Power Electronics and Drive Systems, 14(1), 256–265. https://doi.org/10.11591/ijpeds.v14.i1.pp256-265
Salin
IEEE
P. N. Kabra, S. V. N. L. Lalitha, and S. R. Donepudi, “Bad data analysis and detection using PMU with UPQC integration to grid during fault conditions,” International Journal of Power Electronics and Drive Systems, vol. 14, no. 1, pp. 256–265, 2023, doi: 10.11591/ijpeds.v14.i1.pp256-265.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.