Abstrak

This work includes the establishment of a Photovoltaic system connected to the grid by means of an inverter. The fundamental goal of the work is to incorporate an advanced active power flow management scheme in order to adopt load at any weather condition along with the advantage of maximum active power flow and zero harmonics from PV inverter to the grid. The outcome of analysis and control design of grid connected PV inverter using a Proportional-Integral (PI) control technique is based on synchronous dq rotating reference frame so as to achieve maximum output voltage and record the active power. It has been observed that the model provides a better rate of stability as compared to the existing topology.

Jaringan kolaborasi para penulis

15 penulis · 29 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • KIIT University
  • ITM University
  • Veer Surendra Sai University of Technology
  • Vignan's Foundation for Science, Technology & Research
  • Poornima University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Arjyadhara PradhanKIIT University4
Prakash Kumar HotaVeer Surendra Sai University of Technology2
Sujit Kumar BhuyanKIIT University2
Jayanta Kumar SahuVignan's Foundation for Science, Technology & Research2
Chitralekha JenaKIIT University2
Lipika NandaKIIT University2
Sampurna PandaITM University2
Rakesh KumarITM University2
Ashish RajPoornima University2
K ChaitanyaAfiliasi tidak diketahui1
Sudhakar SahuKIIT University1
Jyoti Prasad PatraAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Stability analysis of photovoltaic system under grid faults</dc:title>
	<dc:creator>Pati, Nivedita</dc:creator>
	<dc:creator>Panda, Babita</dc:creator>
	<dc:creator>Panda, Bhagabat</dc:creator>
	<dc:description xml:lang="en-US">This work includes the establishment of a Photovoltaic system connected to the grid by means of an inverter. The fundamental goal of the work is to incorporate an advanced active power flow management scheme in order to adopt load at any weather condition along with the advantage of maximum active power flow and zero harmonics from PV inverter to the grid. The outcome of analysis and control design of grid connected PV inverter using a Proportional-Integral (PI) control technique is based on synchronous dq rotating reference frame so as to achieve maximum output voltage and record the active power. It has been observed that the model provides a better rate of stability as compared to the existing topology.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20240</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i2.pp931-941</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 2: June 2020; 931-941</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20240/13149</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Nivedita Pati, Babita Panda, Bhagabat Panda</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>