Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Least mean sixth control approach for three-phase three-wire grid-integrated PV system

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 4 (2021) · hlm. 2131–2139

DOI
10.11591/ijpeds.v12.i4.pp2131-2139
ISSN
2722-256X, 2088-8694
Terbit
2021-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This work proposes an adaptive filter based on a new least mean sixth control approach with incremental conductance method of MPP for 3-phase grid-incorporated photovoltaic (PV) system. The proposed system comprises a PV array, 3-phase DC to AC converter, maximum power point tracker (MPPT), three-phase electronic load, and a 3-phase grid. The combination of solar PV array and the voltage source converter (VSC) supplies power to the grid. The 3-phase inverter as a distribution static synchronous compensator (D-STATCOM) improves the quality of the system performance in case of zero solar irradiation. D-STATCOM also reduces total harmonic distortion (THD) in grid currents, improves power factor, and maintainsa constant voltage at the point of common coupling (PCC). The system modelling and simulation is achieved on MATLAB/Simulink. The proposed system performance has been found satisfactory and conform to IEEE-519 standards.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 26 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Integral University
  • Aligarh Muslim University
  • Imam Abdulrahman Bin Faisal University
  • University of Mumbai
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohd UvaisIntegral University2
Asif Jamil AnsariIntegral University2
Adil SarwarAligarh Muslim University2
Mohammad ShahabuddinIntegral University2
Mohammad Arifuddin MallickIntegral University1
Mohd TariqAligarh Muslim University1
Imtiaz AshrafAligarh Muslim University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Least mean sixth control approach for three-phase three-wire grid-integrated PV system</dc:title>
	<dc:creator>Khan, Touheed</dc:creator>
	<dc:creator>Asim, Mohammed</dc:creator>
	<dc:creator>Manzar, Mohammad Saood</dc:creator>
	<dc:creator>Ibrahim, Md</dc:creator>
	<dc:creator>Ahmed, Shaikh Sadaf Afzal</dc:creator>
	<dc:subject xml:lang="en-US">D-STATCOM; Least mean sixth control; MPPT; Power quality; PV array</dc:subject>
	<dc:description xml:lang="en-US">This work proposes an adaptive filter based on a new least mean sixth control approach with incremental conductance method of MPP for 3-phase grid-incorporated photovoltaic (PV) system. The proposed system comprises a PV array, 3-phase DC to AC converter, maximum power point tracker (MPPT), three-phase electronic load, and a 3-phase grid. The combination of solar PV array and the voltage source converter (VSC) supplies power to the grid. The 3-phase inverter as a distribution static synchronous compensator (D-STATCOM) improves the quality of the system performance in case of zero solar irradiation. D-STATCOM also reduces total harmonic distortion (THD) in grid currents, improves power factor, and maintainsa constant voltage at the point of common coupling (PCC). The system modelling and simulation is achieved on MATLAB/Simulink. The proposed system performance has been found satisfactory and conform to IEEE-519 standards.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21507</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i4.pp2131-2139</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 4: December 2021; 2131-2139</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21507/13609</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Touheed Khan, Mohammed Asim, Mohammad Saood Manzar, Md Ibrahim, Shaikh Sadaf Afzal Ahmed</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>