Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design of a Grid-connected Photovoltaic Inverter with Maximum Power Point Tracking using Perturb and Observe Technique

International Journal of Power Electronics and Drive Systems · Vol. 7 No. 4 (2016) · hlm. 1212–1220

DOI
10.11591/ijpeds.v7.i4.pp1212-1220
ISSN
2722-256X, 2088-8694
Terbit
2016-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

There is no easy way to convert Photovoltaic (PV) energy with high efficiency due to dynamic changes in solar irradiance and temperature. This paper illustrates a control strategy to design and implementation of Maximum Power Point Tracking (MPPT) in a photovoltaic system using Perturb and Observe (P&O) algorithm. The PSIM simulation results confirm proper functioning of the proposed MPPT sub-circuit to achieve a constant 48V DC output from fluctuating voltage of solar panel by varying duty cycle of the MOSFET in the 24V-48V boost converter. The filtered output waveform of the SPWM driven H-bridge inverter via the L-C low pass filter is found to be a pure sine-wave of 48V peak which is then stepped-up 312V peak (220V rms) by using a step up transformer. The frequency of output voltage is found to be 50Hz with a total harmonic distortion (THD) of 0.001 which is much lower than the IEEE 519 standard.

Jaringan kolaborasi para penulis

10 penulis · 17 tautan kepenulisan bersama · 11 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Independent University, Bangladesh
  • University of Technology Malaysia
  • The University of Texas at Arlington
  • The University of Melbourne
  • University of South Carolina
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sumaiya B. AfzalThe University of Melbourne1
Meeyad M. ShababAfiliasi tidak diketahui1
Saurav DasIndependent University, Bangladesh1
Dhiman ChowdhuryUniversity of South Carolina1
Md. Sohel RanaIndependent University, Bangladesh1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of a Grid-connected Photovoltaic Inverter with Maximum Power Point Tracking using Perturb and Observe Technique</dc:title>
	<dc:creator>Razzak, M. Abdur</dc:creator>
	<dc:creator>Bhuiyan, Wahida Taskin</dc:creator>
	<dc:creator>Natasha, Nawrin Islam</dc:creator>
	<dc:creator>Muzahidul Islam, A K M</dc:creator>
	<dc:creator>Mohammed Amin, Muhamad Kamal</dc:creator>
	<dc:description xml:lang="en-US">There is no easy way to convert Photovoltaic (PV) energy with high efficiency due to dynamic changes in solar irradiance and temperature. This paper illustrates a control strategy to design and implementation of Maximum Power Point Tracking (MPPT) in a photovoltaic system using Perturb and Observe (P&amp;amp;O) algorithm. The PSIM simulation results confirm proper functioning of the proposed MPPT sub-circuit to achieve a constant 48V DC output from fluctuating voltage of solar panel by varying duty cycle of the MOSFET in the 24V-48V boost converter. The filtered output waveform of the SPWM driven H-bridge inverter via the L-C low pass filter is found to be a pure sine-wave of 48V peak which is then stepped-up 312V peak (220V rms) by using a step up transformer. The frequency of output voltage is found to be 50Hz with a total harmonic distortion (THD) of 0.001 which is much lower than the IEEE 519 standard.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2016-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5837</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v7.i4.pp1212-1220</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 7, No 4: December 2016; 1212-1220</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v7.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5837/7540</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 M. Abdur Razzak, Wahida Taskin Bhuiyan, Nawrin Islam Natasha, A K M Muzahidul Islam, Muhamad Kamal Mohammed Amin</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>