Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

SHE PWM based 21 level inverters with hardware analysis

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 2 (2024) · hlm. 993–1000

DOI
10.11591/ijpeds.v15.i2.pp993-1000
ISSN
2722-256X, 2088-8694
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Recently, the advancement of multilevel inverters (MLI) has been a crucial factor in high power and medium voltage applications. This MLI has multiple topologies and has been used in a variety of applications. Cascaded MLI is preferred over other forms of multilevel inverter topologies. Nonetheless, significant obstacles are encountered when implementing these topologies. They necessitate an increased number of switches, DC sources, capacitors, and diodes. Increased losses and total harmonic distortion (THD) will be present in the system. In addition, the MLI is more expensive. The better construction of a multilevel inverter results in more output levels with fewer switches, sources, and driver circuits, as well as low THD. A new single-phase cascaded asymmetrical DC voltage sources based multilevel inverter design and the selective harmonic elimination (SHE) approach are used to attain these goals. After confirming in MATLAB/Simulink, the hardware implementation of the multilevel inverter in 21 levels was completed in this article.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 42 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Galgotias College of Engineering & Technology
  • Galgotias University
  • Anna University, Chennai
  • SRM Institute of Science and Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kanhaiya KumarGalgotias University2
Lokesh VarshneyGalgotias University2
Vrinda MittalGalgotias College of Engineering & Technology1
Prashant ChandraGalgotias College of Engineering & Technology1
Sachin PrakashGalgotias College of Engineering & Technology1
Namya KhanGalgotias College of Engineering & Technology1
Inayat AliGalgotias College of Engineering & Technology1
Ashish RajputGalgotias College of Engineering & Technology1
Anant BhatnagarGalgotias College of Engineering & Technology1
Sajal OmarGalgotias College of Engineering & Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">SHE PWM based 21 level inverters with hardware analysis</dc:title>
	<dc:creator>Arulappan, Annai Theresa Alphonse</dc:creator>
	<dc:creator>Selvaraj, Malathi</dc:creator>
	<dc:creator>Aladian, Ambikapathy</dc:creator>
	<dc:subject xml:lang="en-US">21 levels; cascaded asymmetrical DC voltage source based MLI; multilevel inverters; selective harmonic elimination; total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">Recently, the advancement of multilevel inverters (MLI) has been a crucial factor in high power and medium voltage applications. This MLI has multiple topologies and has been used in a variety of applications. Cascaded MLI is preferred over other forms of multilevel inverter topologies. Nonetheless, significant obstacles are encountered when implementing these topologies. They necessitate an increased number of switches, DC sources, capacitors, and diodes. Increased losses and total harmonic distortion (THD) will be present in the system. In addition, the MLI is more expensive. The better construction of a multilevel inverter results in more output levels with fewer switches, sources, and driver circuits, as well as low THD. A new single-phase cascaded asymmetrical DC voltage sources based multilevel inverter design and the selective harmonic elimination (SHE) approach are used to attain these goals. After confirming in MATLAB/Simulink, the hardware implementation of the multilevel inverter in 21 levels was completed in this article.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23062</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i2.pp993-1000</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 2: June 2024; 993-1000</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23062/14514</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Annai Theresa A</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>