Abstrak

Current source inverter (CSI) operates to output a specified ac current waveform from dc current sources. Talking about power quality, harmonics distortion of ac waveform is a problem of an inverter circuit. Generating a multilevel current waveform will have less harmonics content than a traditional three-level current waveform. In addition to non-ideal conditions of power switches, i.e. voltage drop in diodes, conductors or controlled switches, the performance of current controller applied in an inverter circuit will considerably affect the ac waveform quality produced by inverter circuit. This paper presents and discusses application of hysteresis current controller in the five-level H-bridge with inductor-cell current source inverter. The current controller performance was compared with the proportional integral current controller. Some test results are presented and discussed to explore the advantages of hysteresis controller in reducing the current ripple and harmonics distortion of output current.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 38 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jenderal Soedirman University
  • Tun Hussein Onn University of Malaysia
  • Shizuoka University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Daru Tri NugrohoJenderal Soedirman University5
Toshihiko NoguchiShizuoka University4
Hari SiswantoroJenderal Soedirman University4
Azis Wisnu Widhi NugrahaJenderal Soedirman University3
Wahyu Mulyo UtomoTun Hussein Onn University of Malaysia2
Afarulrazi Abu BakarTun Hussein Onn University of Malaysia2
Hari PrasetijoJenderal Soedirman University2
Retno SupriyantiJenderal Soedirman University2
Amran AmranJenderal Soedirman University1
Abdullah Nur AzizJenderal Soedirman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Improving output current of inductor-cell based five-level CSI using hysteresis current controller</dc:title>
	<dc:creator>Suroso, Suroso</dc:creator>
	<dc:creator>Winasis, Winasis</dc:creator>
	<dc:creator>Priswanto, Priswanto</dc:creator>
	<dc:creator>Sholikhah, Sholikhah</dc:creator>
	<dc:subject xml:lang="en-US">Inverter, Power inductor, Ripple</dc:subject>
	<dc:description xml:lang="en-US">Current source inverter (CSI) operates to output a specified ac current waveform from dc current sources. Talking about power quality, harmonics distortion of ac waveform is a problem of an inverter circuit. Generating a multilevel current waveform will have less harmonics content than a traditional three-level current waveform. In addition to non-ideal conditions of power switches, i.e. voltage drop in diodes, conductors or controlled switches, the performance of current controller applied in an inverter circuit will considerably affect the ac waveform quality produced by inverter circuit. This paper presents and discusses application of hysteresis current controller in the five-level H-bridge with inductor-cell current source inverter. The current controller performance was compared with the proportional integral current controller. Some test results are presented and discussed to explore the advantages of hysteresis controller in reducing the current ripple and harmonics distortion of output current.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20891</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i1.pp249-257</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 1: March 2021; 249-257</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20891/13344</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Suroso Suroso, Winasis Winasis, Priswanto Priswanto, Sholikhah Sholikhah</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>