Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Harmonic Comparison of Three Phase Direct Matrix Converter for Reactive Load with Balance and Unbalance Supply Voltage

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 1 (2018) · hlm. 345–356

DOI
10.11591/ijpeds.v9.i1.pp345-356
ISSN
2722-256X, 2088-8694
Terbit
2018-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents harmonic analysis of matrix converter using different control technique for balance and Unbalance three phase input voltage of reactive load. Since Matrix converter is subject to affected either by external disturbance or by load conditions. Due to this the supply voltage becomes unbalance. This cause improper switching of matrix converter results higher harmonics. This harmonics are harmful to the quality of the output power. The switching sequence of the matrix converter is controlled by vector control method. Different control technique is proposed in this paper to get optimized result with reduced harmonic for unbalanced and balance input voltage using PID, Fractional Order PID (PIλDδ) controller (FOPID), Particle Swarm Optimization (PSO)FOPID. PID control technique result are compared with other optimization technique for best optimum output. The FOPID controller is used to compensates the current and also improvise the quality of energy by reducing the harmonic content. The simulations and hardware results will be presented and interpreted. The effectivess of the proposed system is proven with the results is shown in this paper which produce a better steady state lesser transient rather than the conventional PID method.

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vellore Institute of Technology University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Harmonic Comparison of Three Phase Direct Matrix Converter for Reactive Load with Balance and Unbalance Supply Voltage</dc:title>
	<dc:creator>K.V, Kandasamy</dc:creator>
	<dc:creator>Sahoo, Sarat Kumar</dc:creator>
	<dc:description xml:lang="en-US">This paper presents harmonic analysis of matrix converter using different control technique for balance and Unbalance three phase input voltage of reactive load. Since Matrix converter is subject to affected either by external disturbance or by load conditions. Due to this the supply voltage becomes unbalance. This cause improper switching of matrix converter results higher harmonics. This harmonics are harmful to the quality of the output power. The switching sequence of the matrix converter is controlled by vector control method. Different control technique is proposed in this paper to get optimized result with reduced harmonic for unbalanced and balance input voltage using PID, Fractional Order PID (PIλDδ) controller (FOPID), Particle Swarm Optimization (PSO)FOPID. PID control technique result are compared with other optimization technique for best optimum output. The FOPID controller is used to compensates the current and also improvise the quality of energy by reducing the harmonic content. The simulations and hardware results will be presented and interpreted. The effectivess of the proposed system is proven with the results is shown in this paper which produce a better steady state lesser transient rather than the conventional PID method.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Department of Science and Technology (DST), Government of India, Project No. DST/TSG/NTS/2013/59.</dc:contributor>
	<dc:date>2018-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8322</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i1.pp345-356</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 1: March 2018; 345-356</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8322/11142</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Kandasamy K.V, Sarat Kumar Sahoo</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>