Abstrak

Generally, PV cell converts sunlight into electricity in the form of dc. Integration of PV system with the existing grid requires dc-ac conversion. This conversion is possible with the help of a dc-ac converter known as an inverter. Among all types of the inverter, multilevel inverters (MLIs) are playing a major role with all their major privileges like High power quality, low distortion, less blocking voltages for switching devices. Conventional multilevel inverter topologies such as diode clamped, flying capacitor and cascaded MLIs are having so many disadvantages. One of the common disadvantage among all the conventional MLIs is the requirement of more number of power electronic components as the level of the output voltage increase. To reduce the power electronic components this paper proposes a multilevel inverter topology in symmetrical and asymmetrical configuration. The proposed MLI uses 12 switches and 19 diodes which are very less compared to conventional MLI topologies for generates nine and thirteen level output voltages. Comparison between presented MLI topology and conventional MLI topologies is presented in this paper. Finally, the proposed MLI whose input is fed from the PV system is integrated into the grid. The proposed concept is validated by using the MATLAB/SIMULINK software and the appropriate results are presented in this paper.

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
K V Krishna RaoAfiliasi tidak diketahui1
P Bala Koteswara RaoAfiliasi tidak diketahui1
T. AbishaiKoneru Lakshmaiah Education Foundation1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Grid Interconnection of PV System Using Symmetric and Asymmetric MLI Topology</dc:title>
	<dc:creator>Prasadarao K, V S</dc:creator>
	<dc:creator>Manohar, V Joshi</dc:creator>
	<dc:description xml:lang="en-US">Generally, PV cell converts sunlight into electricity in the form of dc. Integration of PV system with the existing grid requires dc-ac conversion. This conversion is possible with the help of a dc-ac converter known as an inverter. Among all types of the inverter, multilevel inverters (MLIs) are playing a major role with all their major privileges like High power quality, low distortion, less blocking voltages for switching devices. Conventional multilevel inverter topologies such as diode clamped, flying capacitor and cascaded MLIs are having so many disadvantages. One of the common disadvantage among all the conventional MLIs is the requirement of more number of power electronic components as the level of the output voltage increase. To reduce the power electronic components this paper proposes a multilevel inverter topology in symmetrical and asymmetrical configuration. The proposed MLI uses 12 switches and 19 diodes which are very less compared to conventional MLI topologies for generates nine and thirteen level output voltages. Comparison between presented MLI topology and conventional MLI topologies is presented in this paper. Finally, the proposed MLI whose input is fed from the PV system is integrated into the grid. The proposed concept is validated by using the MATLAB/SIMULINK software and the appropriate results are presented in this paper.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15522</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i4.pp1616-1623</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 4: December 2018; 1616-1623</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15522/11466</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 V S Prasadarao K, V Joshi Manohar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>