Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Fault Detection & Classification in UPFC Integrated Transmission Line Using DWT

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 4 (2017) · hlm. 1793–1803

DOI
10.11591/ijpeds.v8.i4.pp1793-1803
ISSN
2722-256X, 2088-8694
Terbit
2017-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Fault detection and classification in UPFC (Unified Power Flow Controller) integrated transmission line using single terminal based DWT (Discrete Wavelet Transform) is proposed. The current is extracted from the sending end bus and processed through wavelet transform to evaluate the spectral energy (SE) using db4 mother wavelet. Three level decomposition is framed to extract the fundamental frequency component from non-stationary signal, considering sampling frequency of 2kHz system. The fundamental frequency component of respective phase currents are used to compute SE at sending end. The SE of individual phase current is the key factor for deciding the fault pattern detection and classification. The advantage of using this it requires less cost and protect entire transmission line with minimal fault detection time. The various types of fault (L-G, L-L, L-L-G, L-L-L) are simulated by considering the parameter like fault resistance, source impedance, fault inception angle, multi-location fault, reverse power flow and UPFC system parameter. The scheme works reliable and efficient to detect and classify the fault within a cycle of sample period 40 or a cycle of time period 20ms compared to other conventional relaying scheme.

Jaringan kolaborasi para penulis

11 penulis · 15 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • KIIT University
  • G H Raisoni University
  • Biju Patnaik University of Technology
  • REVA University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ritesh Kumar DashREVA University1
Sanhita MishraKIIT University1
Mrutyunjaya MangarajAfiliasi tidak diketahui1
Rohan Vijay ThakurG H Raisoni University1
S.C SwainKIIT University1
Lokanath TripathyBiju Patnaik University of Technology1
Sujit Kumar BhuyanKIIT University1
Pranita RathodG H Raisoni University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Fault Detection &amp; Classification in UPFC Integrated Transmission Line Using DWT</dc:title>
	<dc:creator>Mishra, Sanjay Kumar</dc:creator>
	<dc:creator>Swain, Sarat Chandra</dc:creator>
	<dc:creator>Tripathy, Loknath</dc:creator>
	<dc:description xml:lang="en-US">Fault detection and classification in UPFC (Unified Power Flow Controller) integrated transmission line using single terminal based DWT (Discrete Wavelet Transform) is proposed. The current is extracted from the sending end bus and processed through wavelet transform to evaluate the spectral energy (SE) using db4 mother wavelet. Three level decomposition is framed to extract the fundamental frequency component from non-stationary signal, considering sampling frequency of 2kHz system. The fundamental frequency component of respective phase currents are used to compute SE at sending end. The SE of individual phase current is the key factor for deciding the fault pattern detection and classification. The advantage of using this it requires less cost and protect entire transmission line with minimal fault detection time. The various types of fault (L-G, L-L, L-L-G, L-L-L) are simulated by considering the parameter like fault resistance, source impedance, fault inception angle, multi-location fault, reverse power flow and UPFC system parameter. The scheme works reliable and efficient to detect and classify the fault within a cycle of sample period 40 or a cycle of time period 20ms compared to other conventional relaying scheme.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8519</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i4.pp1793-1803</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 4: December 2017; 1793-1803</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/8519/7907</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Sanjay Kumar Mishra, Sarat Chandra Swain, Loknath Tripathy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>