Experimental and simulation approach of cooling system in 3-phase inverter using extended surface

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 4 (2022) · hlm. 2313–2323

DOI
10.11591/ijpeds.v13.i4.pp2313-2323
ISSN
2722-256X, 2088-8694
Terbit
2022-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Overheating is a failure mode that significantly affects the reliability of electronic devices. All electronic devices, including a 3-phase inverter driving a traction motor, produce heat dissipation. Heat dissipation needs to be controlled with cooling to prevent overheating. Overheating can be avoided by increasing cooling or reducing heat dissipation. Heat dissipation in the 3-phase inverter is caused by the internal resistance of the metal–oxide–semiconductor field-effect transistor (MOSFET), switching loss, and other factors. Cooling for the 3-phase inverter can use water coolant or air coolant. The cooling system is based on the amount of heat dissipation produced. Cooling of a 3-phase inverter can use air coolant with the addition of an extended surface area in the heat sink. The heat sink uses aluminum material, often called pin fin. There are kinds of aluminum available in the market. We calculated heat generation based on the MOSFET's internal resistance, switching loss, and other factors. We validated the simulation results experimentally using a thermal camera. Thus, we could find an optimal number, dimensions, and aluminum type of fin for the cooling system in the 3-phase inverter.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 117 tautan kepenulisan bersama · 72 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Institut Teknologi Sepuluh Nopember
  • Telkom University
  • Universiti Malaysia Perlis
  • Chittagong University of Engineering & Technology
  • Universitas Negeri Surabaya
  • American International University-Bangladesh
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
P. VigneshwaranSRM Institute of Science and Technology5
Andino MaselenoUniversiti Tenaga Nasional3
Brahmantya Aji PramuditaTelkom University2
Sigit Dani PerkasaUniversitas Airlangga2
Agung Prijo BudijonoUniversitas Negeri Surabaya2
Agus Sigit PramonoInstitut Teknologi Sepuluh Nopember2
Kunal KunalGuru Gobind Singh Indraprastha University2
Mian Usman SattarUniversity of Management and Technology2
Omar TananeUniversity of Hassan II Casablanca2
Dimas Febriyan PriambodoPoliteknik Siber dan Sandi Negara2
Hafidz Faqih Aldi KusumaUniversitas Airlangga2
Yusrizal AfifUniversitas Airlangga2
Safaa Najah Saud Al-HumairiAfiliasi tidak diketahui2
Arya Dwi KustiawanUniversitas Airlangga2
Muhammad Rafi Nabil ArsalanUniversitas Airlangga2
Rizki Putra PrastioUniversitas Airlangga2
Muhammad Nur YuniartoInstitut Teknologi Sepuluh Nopember2
Herlambang SetiadiUniversitas Airlangga1
Hazlie MokhlisUniversity of Malaya1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Muhd Hafizi IdrisUniversiti Malaysia Perlis1
Mohammad Faridun Naim TajuddinUniversiti Malaysia Perlis1
Mohammad Aldrin ArifinTelkom University1
Porman PangaribuanTelkom University1
Saad MekhilefSwinburne University of Technology1
Aditta ChowdhuryChittagong University of Engineering & Technology1
Monirul Islam MiskatChittagong University of Engineering & Technology1
Tofael AhmedChittagong University of Engineering & Technology1
Shameem AhmadAmerican International University-Bangladesh1
Md. Rifat HazariAmerican International University-Bangladesh1
Nayu Nurrohma HidayahUniversitas Airlangga1
Aris PurwantoUniversitas Negeri Surabaya1
Po-Hung LinNational Cheng Kung University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Experimental and simulation approach of cooling system in  3-phase inverter using extended surface</dc:title>
	<dc:creator>Mukhlisin, Agus</dc:creator>
	<dc:creator>Megantoro, Prisma</dc:creator>
	<dc:creator>Rijanto, Estiko</dc:creator>
	<dc:creator>Sutantra, I Nyoman</dc:creator>
	<dc:creator>Awalin, Lilik Jamilatul</dc:creator>
	<dc:creator>Nugraha, Yoga Uta</dc:creator>
	<dc:creator>Sidharta, Indra</dc:creator>
	<dc:subject xml:lang="en-US">3-phase inverter; Cooling system; Extended surface; Heat dissipation; Heat sinks</dc:subject>
	<dc:description xml:lang="en-US">Overheating is a failure mode that significantly affects the reliability of electronic devices. All electronic devices, including a 3-phase inverter driving a traction motor, produce heat dissipation. Heat dissipation needs to be controlled with cooling to prevent overheating. Overheating can be avoided by increasing cooling or reducing heat dissipation. Heat dissipation in the 3-phase inverter is caused by the internal resistance of the metal–oxide–semiconductor field-effect transistor (MOSFET), switching loss, and other factors. Cooling for the 3-phase inverter can use water coolant or air coolant. The cooling system is based on the amount of heat dissipation produced. Cooling of a 3-phase inverter can use air coolant with the addition of an extended surface area in the heat sink. The heat sink uses aluminum material, often called pin fin. There are kinds of aluminum available in the market. We calculated heat generation based on the MOSFET's internal resistance, switching loss, and other factors. We validated the simulation results experimentally using a thermal camera. Thus, we could find an optimal number, dimensions, and aluminum type of fin for the cooling system in the 3-phase inverter.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Airlangga University, Faculty of Advanced Technology and Multidiscipline, Electrical Engineering Department</dc:contributor>
	<dc:date>2022-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22054</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i4.pp2313-2323</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 4: December 2022; 2313-2323</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22054/14023</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Agus Mukhlisin, Prisma Megantoro, Estiko Rijanto, I Nyoman Sutantra, Lilik Jamilatul Awalin, Yoga Uta Nugraha, Indra Sidharta</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>