Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

THD performance of single phase five level inverter using proportional resonant and harmonic compensators current controller

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 3 (2020) · hlm. 1423–1429

DOI
10.11591/ijpeds.v11.i3.pp1423-1429
ISSN
2722-256X, 2088-8694
Terbit
2020-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper observe the total harmonic distortion (THD) performance of single phase five level inverter using proportional resonant (PR) and harmonic compensators current controller. The THD when adding PR current controller was 1.6% at first. After more functions were added to the PR current controller to reduce the THD at the 3rd, 5th and 7th harmonic orders, the THD of the 3rd harmonic order was reduced from 0.45% to 0.1% while the 5th and 7th harmonic orders were reduced from 0.6% and 0.43% to 0.25% and 0.4% respectively. The development and simulation is performed using Matlab/Simulink. The simulation result is performed by using Fast Fourier Transform analysis (FFT) for the harmonics captured.

Jaringan kolaborasi para penulis

16 penulis · 45 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tun Hussein Onn University of Malaysia
  • Universitas Widya Gama Malang
  • Diponegoro University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Siti Amely JumaatTun Hussein Onn University of Malaysia2
Ahmad Fateh Mohamad NorTun Hussein Onn University of Malaysia2
Mohd Noor AbdullahTun Hussein Onn University of Malaysia2
Mohd Noor AbdullahTun Hussein Onn University of Malaysia1
Nur Amirah Abdul JamilTun Hussein Onn University of Malaysia1
Nur Hanis Mohammad RadziTun Hussein Onn University of Malaysia1
Ong Wei LiangTun Hussein Onn University of Malaysia1
Rohaiza HamdanTun Hussein Onn University of Malaysia1
Muhammad Nafis IsmailTun Hussein Onn University of Malaysia1
Widjonarko WidjonarkoDiponegoro University1
Wahyu Mulyo UtomoTun Hussein Onn University of Malaysia1
Afarulrazi Abu BakarTun Hussein Onn University of Malaysia1
Nor Farisha DianaTun Hussein Onn University of Malaysia1
Gigih PriyandokoUniversitas Widya Gama Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">THD performance of single phase five level inverter using proportional resonant and harmonic compensators current controller</dc:title>
	<dc:creator>Mohamed, Abdullahi</dc:creator>
	<dc:creator>Salimin, Suriana</dc:creator>
	<dc:description xml:lang="en-US">This paper observe the total harmonic distortion (THD) performance of single phase five level inverter using proportional resonant (PR) and harmonic compensators current controller. The THD when adding PR current controller was 1.6% at first. After more functions were added to the PR current controller to reduce the THD at the 3rd, 5th and 7th harmonic orders, the THD of the 3rd harmonic order was reduced from 0.45% to 0.1% while the 5th and 7th harmonic orders were reduced from 0.6% and 0.43% to 0.25% and 0.4% respectively. The development and simulation is performed using Matlab/Simulink. The simulation result is performed by using Fast Fourier Transform analysis (FFT) for the harmonics captured.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20810</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1423-1429</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1423-1429</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20810/13191</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Abdullahi Mohamed, Suriana Salimin</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>