Abstrak

In this paper, a generalized three-phase multilevel power inverter (MLI) structure is proposed under asymmetric configurations. The operating mode and the switching combinations are briefly exposed according to the parity of the number of direct current (DC) voltage sources in use. Subsequently, the proposed topology is evaluated in terms of commonly used factors and then benchmarked against some of the state-of the-art cascaded MLIs featuring multiple DC voltage sources (MDCS-CMLIs) while putting emphasis on the reduction of power switching devices. Moreover, a new nearest level control (NLC)-based modulation technique is designed for the purpose of better comply with some quality grid codes, namely the European EN 50160 and the International IEC 61000-2-12. The identification of the optimal control thresholds is realized by a constrained optimization algorithm (e.g., particle swarm optimization (PSO)) which is implemented in python script and validated through SIMULINK fast fourier transform (FFT) analysis tool. Lastly, the harmonic performance of the proposed technique is compared side-by-side with that of the conventional NLC scheme and exhibits significant reduction in harmonic distortion.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohammed V University
  • Université de Nouakchott
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yarba AhmedUniversité de Nouakchott1
Aichetoune OumarUniversité de Nouakchott1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Low switching frequency modulation for generalized three-phase multilevel inverters geared toward Grid Codes compliance</dc:title>
	<dc:creator>Setti, Mohammed</dc:creator>
	<dc:creator>Cherkaoui, Mohamed</dc:creator>
	<dc:subject xml:lang="en-US">Nearest level control; Nonlinear constrained optimization; Power quality grid codes; Reduced switch; Three-phase cascaded multilevel inverter</dc:subject>
	<dc:description xml:lang="en-US">In this paper, a generalized three-phase multilevel power inverter (MLI) structure is proposed under asymmetric configurations. The operating mode and the switching combinations are briefly exposed according to the parity of the number of direct current (DC) voltage sources in use. Subsequently, the proposed topology is evaluated in terms of commonly used factors and then benchmarked against some of the state-of the-art cascaded MLIs featuring multiple DC voltage sources (MDCS-CMLIs) while putting emphasis on the reduction of power switching devices. Moreover, a new nearest level control (NLC)-based modulation technique is designed for the purpose of better comply with some quality grid codes, namely the European EN 50160 and the International IEC 61000-2-12. The identification of the optimal control thresholds is realized by a constrained optimization algorithm (e.g., particle swarm optimization (PSO)) which is implemented in python script and validated through SIMULINK fast fourier transform (FFT) analysis tool. Lastly, the harmonic performance of the proposed technique is compared side-by-side with that of the conventional NLC scheme and exhibits significant reduction in harmonic distortion.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21512</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i4.pp2349-2357</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 4: December 2021; 2349-2357</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21512/13580</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Mohammed Setti, Mohamed Cherkaoui</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>