Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Implementation of Harris Hawks optimization for load frequency control of hydropower plant

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 2 (2022) · hlm. 1093–1100

DOI
10.11591/ijpeds.v13.i2.pp1093-1100
ISSN
2722-256X, 2088-8694
Terbit
2022-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Hydropower has been used for many years and is essential to meet the renewable energy ambition of the world at present. In a hydroelectric power plant, voltage and frequency control are required, but, the voltage control could be done on the load side. In the present paper, frequency control using Harris Hawks optimization (HHO) for improved performance has been presented. Simulations are performed on the dynamic model of the hydropower plant and results are compared with the conventional PID that is designed using the Ziegler-Nichols method. The efficacy of the proposed algorithm is also tested at dynamic conditions of the hydropower plant.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 20 tautan kepenulisan bersama · 16 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • VIT-AP University
  • GMR Institute of Technology
  • Gayatri Vidya Parishad College of Engineering for Women
  • Vignan's Foundation for Science, Technology & Research
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ayyarao S. L. V. TummalaGMR Institute of Technology5

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Implementation of Harris Hawks optimization for load frequency control of hydropower plant</dc:title>
	<dc:creator>Potnuru, Devendra</dc:creator>
	<dc:creator>Kumar, Lagudu Venkata Suresh</dc:creator>
	<dc:creator>Sonia, Bankuru</dc:creator>
	<dc:creator>Kumar, Yellapragada Venkata Pavan</dc:creator>
	<dc:creator>Pradeep, Darsy John</dc:creator>
	<dc:creator>Reddy, Challa Pradeep</dc:creator>
	<dc:subject xml:lang="en-US">Harris hawks optimization; Hydropower plant; Load frequency control</dc:subject>
	<dc:description xml:lang="en-US">Hydropower has been used for many years and is essential to meet the renewable energy ambition of the world at present. In a hydroelectric power plant, voltage and frequency control are required, but, the voltage control could be done on the load side. In the present paper, frequency control using Harris Hawks optimization (HHO) for improved performance has been presented. Simulations are performed on the dynamic model of the hydropower plant and results are compared with the conventional PID that is designed using the Ziegler-Nichols method. The efficacy of the proposed algorithm is also tested at dynamic conditions of the hydropower plant.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21931</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i2.pp1093-1100</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 2: June 2022; 1093-1100</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21931/13823</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Devendra Potnuru, Lagudu Venkata Suresh Kumar, Bankuru Sonia, Yellapragada Venkata Pavan Kumar, Darsy John Pradeep, Challa Pradeep Reddy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>