Abstrak

Failures and guaranteed dependability of the electrical grid, early fault diagnosis in power transformers is essential. By examining gas ratios suggestive of faults, dissolved gas analysis (DGA) continues to be a vital component for transformer health monitoring. Using four preprocessing techniques raw data, min-max normalization, logarithmic transformation, and square root transformation; this study suggests a machine learning method for fault detection using DGA gas ratios (such as CH₄/H₂, C₂H₂/C₂H₄). Random forest (RF), support vector machines (SVM), gradient boosted trees (GBT), and a hybrid RF-GBT model that uses prediction fusion were the four supervised classifiers assessed. Performance was assessed using accuracy, precision, recall, f1-score, and Cohen's kappa. Experimental results show that the hybrid RF-GBT model with logarithmic transformation achieves the highest performance, with 94.93% accuracy and 92.37% Cohen's kappa, significantly outperforming individual classifiers. Data preprocessing, particularly logarithmic and square root transformations, enhances diagnostic robustness by mitigating feature skewness. This study underscores the importance of tailored preprocessing and ensemble methods for reliable transformer fault diagnosis.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 48 tautan kepenulisan bersama · 30 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Centre Universitaire Nour Bachir El Bayadh
  • Tunku Abdul Rahman University of Management and Technology
  • University of Malaya
  • Ahmed Zabana University - Relizane
  • Université de ain Témouchent
  • Université Mustapha Stambouli de Mascara
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Latifa SmaïlCentre Universitaire Nour Bachir El Bayadh3
Hocine GuentriCentre Universitaire Nour Bachir El Bayadh2
Ali Abderrazak TadjeddineCentre Universitaire Nour Bachir El Bayadh2
Rim Feyrouz AbdelgouiAhmed Zabana University - Relizane2
Chong Wan XinTunku Abdul Rahman University of Management and Technology1
Wong Jee Keen RaymondTunku Abdul Rahman University of Management and Technology1
Lai Weng KinTunku Abdul Rahman University of Management and Technology1
Yiauw Kah HaurTunku Abdul Rahman University of Management and Technology1
Soumia DjelailaCentre Universitaire Nour Bachir El Bayadh1
A. TadjeddineAfiliasi tidak diketahui1
Kamline MiloudCentre Universitaire Nour Bachir El Bayadh1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Transformer fault diagnosis using dissolved gas analysis: a hybrid ensemble model with data preprocessing</dc:title>
	<dc:creator>Boudjella, Fatima Zohra</dc:creator>
	<dc:creator>Boudjella, Souhila</dc:creator>
	<dc:creator>Ahmed, Nasiru Yahaya</dc:creator>
	<dc:creator>Illias, Hazlee Azil</dc:creator>
	<dc:creator>Latifa, Smail</dc:creator>
	<dc:creator>Hafidha, Reriballah</dc:creator>
	<dc:subject xml:lang="en-US">data preprocessing; dissolved gas analysis; gas ratio methods; hybrid ensemble models; logarithmic transformation; machine learning classifiers; square root transformation</dc:subject>
	<dc:description xml:lang="en-US">Failures and guaranteed dependability of the electrical grid, early fault diagnosis in power transformers is essential. By examining gas ratios suggestive of faults, dissolved gas analysis (DGA) continues to be a vital component for transformer health monitoring. Using four preprocessing techniques raw data, min-max normalization, logarithmic transformation, and square root transformation; this study suggests a machine learning method for fault detection using DGA gas ratios (such as CH₄/H₂, C₂H₂/C₂H₄). Random forest (RF), support vector machines (SVM), gradient boosted trees (GBT), and a hybrid RF-GBT model that uses prediction fusion were the four supervised classifiers assessed. Performance was assessed using accuracy, precision, recall, f1-score, and Cohen's kappa. Experimental results show that the hybrid RF-GBT model with logarithmic transformation achieves the highest performance, with 94.93% accuracy and 92.37% Cohen's kappa, significantly outperforming individual classifiers. Data preprocessing, particularly logarithmic and square root transformations, enhances diagnostic robustness by mitigating feature skewness. This study underscores the importance of tailored preprocessing and ensemble methods for reliable transformer fault diagnosis.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24914</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i3.pp1780-1793</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 3: September 2026; 1780-1793</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24914/15310</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Fatima Zohra Boudjella, Souhila Boudjella, Nasiru Yahaya Ahmed, Hazlee Azil Illias, Smail Latifa, Reriballah Hafidha</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>