Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Islanding Detection of Inverter Based DG Unit Using PV System

International Journal of Power Electronics and Drive Systems · Vol. 4 No. 4 (2014) · hlm. 438–450

ISSN
2722-256X, 2088-8694
Terbit
2014-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Distributed generation (DG) units are rapidly increasing and most of them are interconnected with distribution network to supply power into the network as well as local loads Islanding operations of DG usually occur when power supply from the main utility is interrupted due to several reasons but the DG keeps supplying power into the distribution networks. a new method for islanding detection of inverter-based distributed generation (DG). Although active islanding detection techniques have smaller non detection zones than passive techniques, active methods could degrade the system power quality and are not as simple and easy to implement as passive methods. The phenomenon of unintentional islanding occurs when a distributed generator (DG) continues to feed power into the grid when power flow from the central utility source has been interrupted. A simple islanding detection scheme has been designed based on this idea. The proposed method has been studied under multiple-DG operation modes and the UL 1741 islanding tests. The simulations results, carried out by MATLAB/Simulink, show that the proposed method has a small Non detection zone.DOI: http://dx.doi.org/10.11591/ijpeds.v4i4.6257

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Islanding Detection of Inverter Based DG Unit Using PV System</dc:title>
	<dc:creator>Divyasree, M.</dc:creator>
	<dc:creator>Narasimha Rao, L.Venkata</dc:creator>
	<dc:description xml:lang="en-US">Distributed generation (DG) units are rapidly increasing and most of them are interconnected with distribution network to supply power into the network as well as local loads Islanding operations of DG usually occur when power supply from the main utility is interrupted due to several reasons but the DG keeps supplying power into the distribution networks. a new method for islanding detection of inverter-based distributed generation (DG). Although active islanding detection techniques have smaller non detection zones than passive techniques, active methods could degrade the system power quality and are not as simple and easy to implement as passive methods. The phenomenon of unintentional islanding occurs when a distributed generator (DG) continues to feed power into the grid when power flow from the central utility source has been interrupted. A simple islanding detection scheme has been designed based on this idea. The proposed method has been studied under multiple-DG operation modes and the UL 1741 islanding tests. The simulations results, carried out by MATLAB/Simulink, show that the proposed method has a small Non detection zone.DOI: http://dx.doi.org/10.11591/ijpeds.v4i4.6257</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2014-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5017</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 4, No 4: December 2014; 438-450</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v4.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/5017/4728</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2014 M. Divyasree, L.Venkata Narasimha Rao</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>