Abstrak

Since the previous few decades, researchers and utilities have been extremely concerned about voltage instability because to the numerous instances of system blackouts caused by voltage instability that have been recorded in various regions of the world. With the development of synchro phasor technology, it appears conceivable to track and manage the system's voltage stability in real time. This study suggests using phasor measuring units (PMUs) placed strategically to monitor voltage stability margin online and to regulate it using a static synchronous compensator (STATCOM). According to the minimum reactive and real power loanability for the most of the line outages, STATCOM has been installed at the critical bus. Based on the difference between the bus voltage and its reference value, STATCOM supplies reactive power into the bus. PMU measurements are used to determine bus voltages at regular intervals, and reactive power is then added to the bus online as necessary. The increased voltage stability margin brought on by STATCOM injecting reactive power is continuously checked. Based on simulations performed on the IEEE 14-bus system and the New England 39-bus system, the effectiveness of the suggested approach for online monitoring and management of voltage stability margin (VSM) has been proven.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 15 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sri Venkateswara University
  • SASTRA University
  • Koneru Lakshmaiah Education Foundation
  • Sri Venkateswara College of Engineering Tirupati
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Pasala GopiKoneru Lakshmaiah Education Foundation2
D. SarikaAfiliasi tidak diketahui2
Suresh Babu PotladurtySri Venkateswara College of Engineering Tirupati2
A. V. Sudhakara ReddySri Venkateswara University1
Moupuri Satish Kumar ReddySASTRA University1
M. Laxmidevi RamanaiahSri Venkateswara University1
Ganesh ChallaSri Venkateswara University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Voltage stability assessment using PMUs and STATCOM</dc:title>
	<dc:creator>Palepu, Suresh Babu</dc:creator>
	<dc:creator>Reddy, Manubolu Damodar</dc:creator>
	<dc:subject xml:lang="en-US">Nose curves; PMU; STATCOM; Voltage stability; VSM</dc:subject>
	<dc:description xml:lang="en-US">Since the previous few decades, researchers and utilities have been extremely concerned about voltage instability because to the numerous instances of system blackouts caused by voltage instability that have been recorded in various regions of the world. With the development of synchro phasor technology, it appears conceivable to track and manage the system's voltage stability in real time. This study suggests using phasor measuring units (PMUs) placed strategically to monitor voltage stability margin online and to regulate it using a static synchronous compensator (STATCOM). According to the minimum reactive and real power loanability for the most of the line outages, STATCOM has been installed at the critical bus. Based on the difference between the bus voltage and its reference value, STATCOM supplies reactive power into the bus. PMU measurements are used to determine bus voltages at regular intervals, and reactive power is then added to the bus online as necessary. The increased voltage stability margin brought on by STATCOM injecting reactive power is continuously checked. Based on simulations performed on the IEEE 14-bus system and the New England 39-bus system, the effectiveness of the suggested approach for online monitoring and management of voltage stability margin (VSM) has been proven.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2023-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22086</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i1.pp1-10</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 1: March 2023; 1-10</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22086/14056</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Suresh Babu Palepu, Manubolu Damodar Reddy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>