Abstrak

The power plants behavior is crucial under faulted conditions and responses on protection systems. Major microgrid (MG) protection problem is the problem between the fault current in utilitygrid mode and microgrid mode. As conventional protection system doesn’t offer solution for all MG protection challenge, but it needs advanced protection strategy. Protection system must response to both the utilitygrid and MG faults. Fast response of protection is necessary as early as possible if the fault is occurs on utilitygrid and if the fault is occurs on MG, the protection scheme must seperate the small possible portion of MG to remove the fault. This work presents a typical MG protection scheme using digital relaying and satellite communication with wavelet detailed D1-coefficients of mother wavelet Bior 1.5. This research work is done for the detection, discrimination and locality of faults at distributed generators (DG’s) integration in multi-terminal transmission system. The algorithm tested under various faults with fault inception angles (FIA), fault impedances and fault distance of feeder line.

Jaringan kolaborasi para penulis

15 penulis · 20 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Koneru Lakshmaiah Education Foundation
  • Deccan College Post Graduate and Research Institute
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ravi PonnalaKoneru Lakshmaiah Education Foundation3
Muktevi ChakravarthyAfiliasi tidak diketahui3
Vellanki Mehar JyothiKoneru Lakshmaiah Education Foundation2
Tadanki Vijay MuniKoneru Lakshmaiah Education Foundation2
S. Chandra ShekarKoneru Lakshmaiah Education Foundation1
Gaurav KumarKoneru Lakshmaiah Education Foundation1
Nachiket A. KulkarniKoneru Lakshmaiah Education Foundation1
Sanjay A. DeokarKoneru Lakshmaiah Education Foundation1
Rajesh DamarajuKoneru Lakshmaiah Education Foundation1
Preeti Nitin KabraDeccan College Post Graduate and Research Institute1
Sudha Rani DonepudiAfiliasi tidak diketahui1
Satyanarayana GorantlaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Renewable energy integrated multi-terminal transmission system using wavelet based protection scheme</dc:title>
	<dc:creator>Sekhar, Savarapu Chandra</dc:creator>
	<dc:creator>Kumar, G. Ravi</dc:creator>
	<dc:creator>Lalitha, S.V.N.L</dc:creator>
	<dc:description xml:lang="en-US">The power plants behavior is crucial under faulted conditions and responses on protection systems. Major microgrid (MG) protection problem is the problem between the fault current in utilitygrid mode and microgrid mode. As conventional protection system doesn’t offer solution for all MG protection challenge, but it needs advanced protection strategy. Protection system must response to both the utilitygrid and MG faults. Fast response of protection is necessary as early as possible if the fault is occurs on utilitygrid and if the fault is occurs on MG, the protection scheme must seperate the small possible portion of MG to remove the fault. This work presents a typical MG protection scheme using digital relaying and satellite communication with wavelet detailed D1-coefficients of mother wavelet Bior 1.5. This research work is done for the detection, discrimination and locality of faults at distributed generators (DG’s) integration in multi-terminal transmission system. The algorithm tested under various faults with fault inception angles (FIA), fault impedances and fault distance of feeder line.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15156</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v10.i2.pp995-1002</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 10, No 2: June 2019; 995-1002</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v10.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/15156/12898</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Savarapu Chandra Sekhar, G. Ravi Kumar, S.V.N.L Lalitha</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>