Active damping and robust loop shaping control for harmonic minimization

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 2 (2021) · hlm. 832–844

DOI
10.11591/ijpeds.v12.i2.pp832-844
ISSN
2722-256X, 2088-8694
Terbit
2021-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents an h-infinity robust loop shaping control and LCL filter to mitigate the effects of harmonic currents in the photovoltaic system integrated with the grid. To eliminate the negative effects of the LCL filter, this work applied notch filter active damping. Existing methods for the elimination of harmonic currents were reviewed. Proportional integral control, fuzzy logic control, h-infinity control, and robust loop shaping control are presented. The grid current was analyzed in the system with all controllers applied to control the voltage source inverter of the system to eliminate harmonics in the grid current caused by the inverter and nonlinear loads for two cases, one being constant loading of the linear and nonlinear load and another is the switching of the nonlinear load during the simulation. The results obtained from the proposed method for the two tests conducted were compared with those from other methods to prove the robustness of the proposed technique. The method manages to reduce the total harmonic distortion of the grid current from 7.85% to 0.79% for case 1 and from 11.67% to 1.14% for case 2.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Walailak University
  • University of Dar es Salaam
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Active damping and robust loop shaping control for harmonic minimization</dc:title>
	<dc:creator>Zongo, Oscar Andrew</dc:creator>
	<dc:creator>Kafuku, John Mbogo</dc:creator>
	<dc:subject xml:lang="en-US">Harmonic current distortion; Power system; Renewable energy technology; Robust loop shaping control; Solar photovoltaic</dc:subject>
	<dc:description xml:lang="en-US">This paper presents an h-infinity robust loop shaping control and LCL filter to mitigate the effects of harmonic currents in the photovoltaic system integrated with the grid. To eliminate the negative effects of the LCL filter, this work applied notch filter active damping. Existing methods for the elimination of harmonic currents were reviewed. Proportional integral control, fuzzy logic control, h-infinity control, and robust loop shaping control are presented. The grid current was analyzed in the system with all controllers applied to control the voltage source inverter of the system to eliminate harmonics in the grid current caused by the inverter and nonlinear loads for two cases, one being constant loading of the linear and nonlinear load and another is the switching of the nonlinear load during the simulation. The results obtained from the proposed method for the two tests conducted were compared with those from other methods to prove the robustness of the proposed technique. The method manages to reduce the total harmonic distortion of the grid current from 7.85% to 0.79% for case 1 and from 11.67% to 1.14% for case 2.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21284</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i2.pp832-844</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 2: June 2021; 832-844</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21284/13560</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Oscar Andrew Zongo, John Mbogo Kafuku</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>