Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Modelling G3 gas as an alternative gas for SF6 using COMSOL multiphysics

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 2 (2022) · hlm. 1101–1110

DOI
10.11591/ijpeds.v13.i2.pp1101-1110
ISSN
2722-256X, 2088-8694
Terbit
2022-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Sulfur hexafluoride (SF6) gas is the most often gas used in high voltage systems as insulating medium and arc quenching because it has many advantages such as high dielectric strength, low boiling point, low toxicity, and stability for a long period. The 1997 Kyoto protocol recommended the elimination of SF6 gas, because its impact on the atmosphere has global warming potential (GWP) equal to 23,500 and an ozone depletion potential (ODP) equal to 0.08. Kyoto protocol recommended alternatives gases for SF6 gas such as CF3CHCL2, and others. In this paper a new gas called a HeptaFluoro-iso-Butyronitrile+CO2 ([(CF3)2CFCN+CO2]) which is known commercially as green global gas (G3) The dielectric strength for the proposed gas is approximately equal to SF6 gas and excellent arc quenching and achieve Kyoto protocol recommendations about using alternative gases with 98% less impact on GWP than SF6 gas also G3 gas maintain the same dimension and overall footprint which is an important economical factor for utilities. The total bond energy analysis of SF6 and G3 gases has been studied. COMSOL multiphysics was used to simulate the SF6 and G3 gases to show the ability of the G3 gas when working in geographic information system (GIS) equipment.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Zagazig University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modelling G3 gas as an alternative gas for SF6 using COMSOL multiphysics</dc:title>
	<dc:creator>El-Zein, Abelatef Mohammed</dc:creator>
	<dc:creator>Ibrahim, Ayman Bdrawy</dc:creator>
	<dc:subject xml:lang="en-US">A-HeptaFluoro-iso-Butyronitrile+CO2) G3 gas; COMSOL multiphysics; Gas insulated switchgear; Sulfur hexafluoride SF6 gas</dc:subject>
	<dc:description xml:lang="en-US">Sulfur hexafluoride (SF6) gas is the most often gas used in high voltage systems as insulating medium and arc quenching because it has many advantages such as high dielectric strength, low boiling point, low toxicity, and stability for a long period. The 1997 Kyoto protocol recommended the elimination of SF6 gas, because its impact on the atmosphere has global warming potential (GWP) equal to 23,500 and an ozone depletion potential (ODP) equal to 0.08. Kyoto protocol recommended alternatives gases for SF6 gas such as CF3CHCL2, and others. In this paper a new gas called a HeptaFluoro-iso-Butyronitrile+CO2 ([(CF3)2CFCN+CO2]) which is known commercially as green global gas (G3) The dielectric strength for the proposed gas is approximately equal to SF6 gas and excellent arc quenching and achieve Kyoto protocol recommendations about using alternative gases with 98% less impact on GWP than SF6 gas also G3 gas maintain the same dimension and overall footprint which is an important economical factor for utilities. The total bond energy analysis of SF6 and G3 gases has been studied. COMSOL multiphysics was used to simulate the SF6 and G3 gases to show the ability of the G3 gas when working in geographic information system (GIS) equipment.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21757</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i2.pp1101-1110</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 2: June 2022; 1101-1110</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21757/13824</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Abelatef Mohammed El-Zein, Ayman Bdrawy Ibrahim</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>