Study of neural controller based MPPT in comparison with P&O for PV systems
International Journal of Power Electronics and Drive Systems · Vol. 17 No. 1 (2026) · hlm. 797–808
ISSN 2722-256X, 2088-8694
Terbit 2026-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
This study investigated the performance of two prominent maximum power point tracking (MPPT) strategies: the established perturb and observe (P&O) technique and an artificial neural network (ANN)-based controller. Through simulations conducted in MATLAB/Simulink, a 50 W photovoltaic (PV) array was evaluated under dynamic irradiance and temperature variations. Notably, data generated by the P&O system served as the training dataset for the ANN model. The simulation results indicate that the ANN controller effectively and accurately identifies the PV system’s optimal operating point even amidst fluctuating environmental conditions. When compared to the conventional P&O method, the ANN approach demonstrated superior characteristics, including a significantly faster response, diminished oscillations around the maximum power point, and enhanced tracking accuracy during rapid environmental shifts. These findings underscore the substantial potential of ANN-based MPPT strategies for improving both the efficiency and operational stability of photovoltaic power systems.
Jaringan kolaborasi para penulis
19 penulis ·
82 tautan kepenulisan bersama
· 49 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Al-Quds University University of Biskra University of Eloued Tomsk Polytechnic University Zagazig University Ahmed Draia University Larbi Ben M'hidi University of Oum El Bouaghi Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Study of neural controller based MPPT in comparison with P&O for PV systems</dc:title>
<dc:creator>Toumi, Djaafar</dc:creator>
<dc:creator>Tiar, Mourad</dc:creator>
<dc:creator>Boucetta, Abir</dc:creator>
<dc:creator>Boucetta, Ikram</dc:creator>
<dc:creator>Ibrahim, Ahmed</dc:creator>
<dc:subject xml:lang="en-US">artificial neural networks; maximum power point tracking; Simulink; P&O; photovoltaic</dc:subject>
<dc:description xml:lang="en-US">This study investigated the performance of two prominent maximum power point tracking (MPPT) strategies: the established perturb and observe (P&amp;O) technique and an artificial neural network (ANN)-based controller. Through simulations conducted in MATLAB/Simulink, a 50 W photovoltaic (PV) array was evaluated under dynamic irradiance and temperature variations. Notably, data generated by the P&amp;O system served as the training dataset for the ANN model. The simulation results indicate that the ANN controller effectively and accurately identifies the PV system’s optimal operating point even amidst fluctuating environmental conditions. When compared to the conventional P&amp;O method, the ANN approach demonstrated superior characteristics, including a significantly faster response, diminished oscillations around the maximum power point, and enhanced tracking accuracy during rapid environmental shifts. These findings underscore the substantial potential of ANN-based MPPT strategies for improving both the efficiency and operational stability of photovoltaic power systems.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24502</dc:identifier>
<dc:identifier>10.11591/ijpeds.v17.i1.pp797-808</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 1: March 2026; 797-808</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v17.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24502/15199</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Mohamed Tayeb Boussabeur, Djaafar Toumi, Mourad Tiar, Abir Boucetta, Ikram Boucetta, Ahmed Ibrahim</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Toumi, D., Tiar, M., Boucetta, A., Boucetta, I., & Ibrahim, A. (2026). Study of neural controller based MPPT in comparison with P&O for PV systems. International Journal of Power Electronics and Drive Systems, 17(1), 797–808. https://doi.org/10.11591/ijpeds.v17.i1.pp797-808
Salin
IEEE
D. Toumi, M. Tiar, A. Boucetta, I. Boucetta, and A. Ibrahim, “Study of neural controller based MPPT in comparison with P&O for PV systems,” International Journal of Power Electronics and Drive Systems, vol. 17, no. 1, pp. 797–808, 2026, doi: 10.11591/ijpeds.v17.i1.pp797-808.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.