Abstrak

This paper presents a grid-connected photovoltaic (PV) interface for delivering both active and reactive powers. The PV interface employs H-bridge topology DC-DC converter and inverter with analog control technology. The power flow is controlled solely by the adjustable DC output voltage of the DC to DC converter. In order to evaluate the PV interface system’s performances, it is tested by delivering power to the grid with low pawer factor. The experimental results show that at 300W active load, the inverter could deliver the reactive power of 400VAR. The PV interface could also produce very low harmonic voltage and current distorsions. The laboratory measurements show that the total harmonic distortions of inverter output voltage and current are 0.46% and 0.05%, respectively

Jaringan kolaborasi para penulis

15 penulis · 40 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tanjungpura University
  • Universiti Sains Malaysia
  • Universitas Muhammadiyah Sumatera Utara
  • Universiti Malaysia Perlis
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ismail YusufTanjungpura University5
Kho Hie KhweeTanjungpura University5
Fitriah HusinAfiliasi tidak diketahui3
F. Trias Pontia WigyariantoTanjungpura University3
Junaidi JunaidiTanjungpura University3
Syaifurrahman SyaifurrahmanTanjungpura University2
Trias Pontia WigyariantoTanjungpura University1
Yohannes M SimanjuntakTanjungpura University1
Muhammad IrwantoUniversiti Malaysia Perlis1
Suwarno SuwarnoUniversitas Muhammadiyah Sumatera Utara1
Fitriah FitriahTanjungpura University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A Grid-Connected Photovoltaic Interface System for Delivering Active and Reactive Powers</dc:title>
	<dc:creator>Mooniarsih, Neilcy T</dc:creator>
	<dc:creator>Masri, Syafrudin</dc:creator>
	<dc:creator>Hafeez, Mohd</dc:creator>
	<dc:creator>Hiendro, Ayong</dc:creator>
	<dc:description xml:lang="en-US">This paper presents a grid-connected photovoltaic (PV) interface for delivering both active and reactive powers. The PV interface employs H-bridge topology DC-DC converter and inverter with analog control technology. The power flow is controlled solely by the adjustable DC output voltage of the DC to DC converter. In order to evaluate the PV interface system’s performances, it is tested by delivering power to the grid with low pawer factor. The experimental results show that at 300W active load, the inverter could deliver the reactive power of 400VAR. The PV interface could also produce very low harmonic voltage and current distorsions. The laboratory measurements show that the total harmonic distortions of inverter output voltage and current are 0.46% and 0.05%, respectively</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11395</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i3.pp1140-1146</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 3: September 2018; 1140-1146</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11395/11310</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Neilcy T Mooniarsih, Syafrudin Masri, Mohd Hafeez, Ayong Hiendro</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>