The optimal order configuration of turbines in a small hydropower plant: A case study of the Lepenci River in Kosovo

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 3 (2022) · hlm. 1675–1683

DOI
10.11591/ijpeds.v13.i3.pp1675-1683
ISSN
2722-256X, 2088-8694
Terbit
2022-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Decentralized electricity production from small hydropower plants used for domestic and ancillary services has been established among the most reliable renewable energy sources for isolated locations. However, many factors impact the energy efficiency and the production capacity of such hydropower plants, one of these factors being the order configuration of the connected turbines. Hence, this research presents a performance evaluation of a small hydropower plant consisting of three francis turbines, and it elicits the optimal order configuration of the connected operating turbines, that yields the highest power output under varying conditions. Three scenarios with different order configurations of turbines are presented and compared in a “run-of-the-river” setting, installed in the Lepenci River, in south-eastern Kosovo. Numerical analyses are used to evaluate the performance of each scenario. The results show that the order configuration of the operating turbines based on their connection order has a significant impact on the electricity production.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 16 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Prishtina
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bukurije HoxhaUniversity of Prishtina3
Sabrije F. OsmanajUniversity of Prishtina2
Drenusha KrasniqiUniversity of Prishtina1
Arianit ZeqiriUniversity of Prishtina1
Drilon MehaUniversity of Prishtina1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The optimal order configuration of turbines in a small hydropower plant: A case study of the Lepenci River in Kosovo</dc:title>
	<dc:creator>Bresa, Arlinda</dc:creator>
	<dc:creator>Dragusha, Bedri</dc:creator>
	<dc:creator>Berisha, Xhevat</dc:creator>
	<dc:creator>Selimaj, Rexhep</dc:creator>
	<dc:subject xml:lang="en-US">Francis turbine; Hydropower plant;  Order configuration;  Renewable energy sources</dc:subject>
	<dc:description xml:lang="en-US">Decentralized electricity production from small hydropower plants used for domestic and ancillary services has been established among the most reliable renewable energy sources for isolated locations. However, many factors impact the energy efficiency and the production capacity of such hydropower plants, one of these factors being the order configuration of the connected turbines. Hence, this research presents a performance evaluation of a small hydropower plant consisting of three francis turbines, and it elicits the optimal order configuration of the connected operating turbines, that yields the highest power output under varying conditions. Three scenarios with different order configurations of turbines are presented and compared in a “run-of-the-river” setting, installed in the Lepenci River, in south-eastern Kosovo. Numerical analyses are used to evaluate the performance of each scenario. The results show that the order configuration of the operating turbines based on their connection order has a significant impact on the electricity production.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21712</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i3.pp1675-1683</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 3: September 2022; 1675-1683</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21712/13967</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Arlinda Bresa, Bedri Dragusha, Xhevat Berisha, Rexhep Selimaj</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>