Grid connected photovoltaic system efficiency and quality improvement using fuzzy-incond MPPT

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 3 (2020) · hlm. 1536–1546

DOI
10.11591/ijpeds.v11.i3.pp1536-1546
ISSN
2722-256X, 2088-8694
Terbit
2020-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Maximum Power Point Tracking (MPPT) techniques are developed to harvest and supply maximum power to the load. This depends on the power generated and the MPPT accuracy. Under quick-changing weather conditions, Incremental Conductance (InCond) and numerous different algorithms may fail to track the exact Maximum Power Point (MPP) which may result in significant power loss. Fuzzy Logic (FL) based MPPT is quick and accurate in tracking the MPP, but the high complexity and the implementation difficulty are their main disadvantages. A novel FL-InCond MPPT improved technique is developed based on the features of InCond and FL techniques to overcome their drawbacks.The newly developed approach can automatically adjust the variation of the duty cycle for tracking the MPP with accuracy. The obtained results are compared with conventional Perturb and observe (P&O) and InCond MPPTs for grid-connected mode under fast weather conditions. It is demonstrated that the developed method outperforms the aforementioned MPPT techniques in terms of tracking response, efficiency and the delivered current quality.

Jaringan kolaborasi para penulis

5 penulis · 8 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Blida
  • University of Jijel
  • University of Boumerdes
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aissa KheldounUniversity of Boumerdes2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Grid connected photovoltaic system efficiency and quality improvement using fuzzy-incond MPPT</dc:title>
	<dc:creator>Yasmine, Amara</dc:creator>
	<dc:creator>Rafik, Bradai</dc:creator>
	<dc:creator>Rachid, Boukenoui</dc:creator>
	<dc:creator>Adel, Mellit</dc:creator>
	<dc:description xml:lang="en-US">Maximum Power Point Tracking (MPPT) techniques are developed to harvest and supply maximum power to the load. This depends on the power generated and the MPPT accuracy. Under quick-changing weather conditions, Incremental Conductance (InCond) and numerous different algorithms may fail to track the exact Maximum Power Point (MPP) which may result in significant power loss. Fuzzy Logic (FL) based MPPT is quick and accurate in tracking the MPP, but the high complexity and the implementation difficulty are their main disadvantages. A novel FL-InCond MPPT improved technique is developed based on the features of InCond and FL techniques to overcome their drawbacks.The newly developed approach can automatically adjust the variation of the duty cycle for tracking the MPP with accuracy. The obtained results are compared with conventional Perturb and observe (P&amp;amp;O) and InCond MPPTs for grid-connected mode under fast weather conditions. It is demonstrated that the developed method outperforms the aforementioned MPPT techniques in terms of tracking response, efficiency and the delivered current quality.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20621</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1536-1546</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1536-1546</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20621/13237</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Amara Yasmine, Bradai Rafik, Boukenoui Rachid, Mellit Adel</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>