Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Droop-free controls of inverter-based generator for use in systems that interconnected with synchronous generators

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 2 (2021) · hlm. 765–771

DOI
10.11591/ijpeds.v12.i2.pp765-771
ISSN
2722-256X, 2088-8694
Terbit
2021-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Because of its simplicity and autonomous operation, droop control technique is widely implemented for power generation control in microgrids. Despite its popularity, it has been reported that the technique has the stability problem. In this paper, the previous work of droop-free inverter-based generator designed for operating in a fix frequency islanded microgrid, is redesigned to have the ability to operate in both islanded and grid connected microgrid as well as to the main power grid where it interconnected with synchronous generators. The proposed voltage source inverters use phase locked loop(PLL) algorithm to synchronize the changing frequency due to the operation of the synchronous generator. Unlike the frequency droop control that the output frequency is varied as its active power changed, the proposed controls do not make an adjustment of the system frequency. This kind of operation reduces the chance of the system unstable due to severe frequency change and it also reduces the frequency deviation when it increases its active power output. Simulation and result of the meshed power network demonstrate the feasibility to implement the proposed controls in thereal system.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 5 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Rajamangala University of Technology Lanna
  • Chiang Mai University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Vishnu ThonglekChiang Mai University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Droop-free controls of inverter-based generator for use in systems that interconnected with synchronous generators</dc:title>
	<dc:creator>Janjornmanit, Suchart</dc:creator>
	<dc:creator>Panta, Sakorn</dc:creator>
	<dc:creator>Nakkrongdee, Wirat</dc:creator>
	<dc:subject xml:lang="en-US">Active power control; Angle control; Microgrid; Power generation control; Reactive power control</dc:subject>
	<dc:description xml:lang="en-US">Because of its simplicity and autonomous operation, droop control technique is widely implemented for power generation control in microgrids. Despite its popularity, it has been reported that the technique has the stability problem. In this paper, the previous work of droop-free inverter-based generator designed for operating in a fix frequency islanded microgrid, is redesigned to have the ability to operate in both islanded and grid connected microgrid as well as to the main power grid where it interconnected with synchronous generators. The proposed voltage source inverters use phase locked loop(PLL) algorithm to synchronize the changing frequency due to the operation of the synchronous generator. Unlike the frequency droop control that the output frequency is varied as its active power changed, the proposed controls do not make an adjustment of the system frequency. This kind of operation reduces the chance of the system unstable due to severe frequency change and it also reduces the frequency deviation when it increases its active power output. Simulation and result of the meshed power network demonstrate the feasibility to implement the proposed controls in thereal system.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Rajamangala University of Technology Lanna</dc:contributor>
	<dc:date>2021-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20944</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i2.pp765-771</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 2: June 2021; 765-771</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20944/13402</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Suchart Janjornmanit, Sakorn Panta, Wirat Nakkrongdee</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>