Akses terbuka
Jurnal
SINTA 1
Optimal FOPID control for improved load frequency regulation of a renewable-integrated hybrid power system using the Puma optimizer
International Journal of Power Electronics and Drive Systems · Vol. 17 No. 3 (2026) · hlm. 2013–2028
ISSN 2722-256X, 2088-8694
Terbit 2026-09-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
This study addresses the challenge of frequency stabilization in a complex two-area hybrid power system subjected to load disturbances. Area 1 comprises thermal, hydro, and wind power generation, while Area 2 integrates thermal, hydro, and gas turbine units, presenting a diverse and realistic system for control strategies. The inherent nonlinearities and varying dynamics of these generation sources, particularly wind power, necessitate a robust and advanced control solution. The proposed Puma optimizer-driven fractional-order proportional-integral-derivative (FOPID) controller is developed to enhance dynamic performance under load disturbances and renewable energy fluctuations. The proposed Puma optimizer-based fractional-order proportional-integral-derivative (PO-FOPID) controller is rigorously validated against a Puma optimizer-based proportional-integral-derivative (PO-PID) controller, a PSO-tuned PID controller, and a PSO-tuned fractional-order PID (PSO-FOPID) controller. The settling time and peak overshoot/undershoot are considered for comparison, while the integral of time multiplied by the absolute error (ITAE) performance index is used as the objective function to be minimized. The findings highlight the potential of combining Puma optimizer with fractional-order control for reliable frequency regulation in modern hybrid power systems.
Jaringan kolaborasi para penulis
26 penulis ·
61 tautan kepenulisan bersama
· 14 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
KIIT University Netaji Subhas University of Technology SR University Centurion University of Technology and Management Vignan's Foundation for Science, Technology & Research Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Optimal FOPID control for improved load frequency regulation of a renewable-integrated hybrid power system using the Puma optimizer</dc:title>
<dc:creator>Samal, Mitali</dc:creator>
<dc:creator>Panigrahi, Chinmoy Kumar</dc:creator>
<dc:creator>Gupta, Deepak Kumar</dc:creator>
<dc:subject xml:lang="en-US">fractional-order proportional-integral-derivative; hybrid power system; load frequency control; particle swarm optimization; puma optimizer</dc:subject>
<dc:description xml:lang="en-US">This study addresses the challenge of frequency stabilization in a complex two-area hybrid power system subjected to load disturbances. Area 1 comprises thermal, hydro, and wind power generation, while Area 2 integrates thermal, hydro, and gas turbine units, presenting a diverse and realistic system for control strategies. The inherent nonlinearities and varying dynamics of these generation sources, particularly wind power, necessitate a robust and advanced control solution. The proposed Puma optimizer-driven fractional-order proportional-integral-derivative (FOPID) controller is developed to enhance dynamic performance under load disturbances and renewable energy fluctuations. The proposed Puma optimizer-based fractional-order proportional-integral-derivative (PO-FOPID) controller is rigorously validated against a Puma optimizer-based proportional-integral-derivative (PO-PID) controller, a PSO-tuned PID controller, and a PSO-tuned fractional-order PID (PSO-FOPID) controller. The settling time and peak overshoot/undershoot are considered for comparison, while the integral of time multiplied by the absolute error (ITAE) performance index is used as the objective function to be minimized. The findings highlight the potential of combining Puma optimizer with fractional-order control for reliable frequency regulation in modern hybrid power systems.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24770</dc:identifier>
<dc:identifier>10.11591/ijpeds.v17.i3.pp2013-2028</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 3: September 2026; 2013-2028</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v17.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24770/15331</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Mitali Samal, Chinmoy Kumar Panigrahi, Deepak Kumar Gupta</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Samal, M., Panigrahi, C. K., & Gupta, D. K. (2026). Optimal FOPID control for improved load frequency regulation of a renewable-integrated hybrid power system using the Puma optimizer. International Journal of Power Electronics and Drive Systems, 17(3), 2013–2028. https://doi.org/10.11591/ijpeds.v17.i3.pp2013-2028
Salin
IEEE
M. Samal, C. K. Panigrahi, and D. K. Gupta, “Optimal FOPID control for improved load frequency regulation of a renewable-integrated hybrid power system using the Puma optimizer,” International Journal of Power Electronics and Drive Systems, vol. 17, no. 3, pp. 2013–2028, 2026, doi: 10.11591/ijpeds.v17.i3.pp2013-2028.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.