Akses terbuka
Jurnal
SINTA 1
Detection of power transmission lines faults based on voltages and currents values using K-nearest neighbors
International Journal of Power Electronics and Drive Systems · Vol. 14 No. 2 (2023) · hlm. 1033–1043
ISSN 2722-256X, 2088-8694
Terbit 2023-06-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The critical factors to consider when implementing a maintenance plan for energy transmission lines are, accuracy, speed, and time, because of the increased global demand for electricity power caused by rapid development, and overuse of electric power transmission lines (both underground cables and overhead transmission lines), which in turn reduces the efficiency of the lines. Consequently, the efficiency of the lines may be reduced as a result of overuse or other activities like excavation that may have tampered with the cables. Thus, it becomes important to investigate the faults to which the lines are exposed. To this end, this article focuses on the detection of fault in transmission lines through the use of k-nearest neighbor algorithm. Using this algorithm, the characteristics were obtained (voltage, current), and these characteristics enable the identification of faults in the transmission lines, and in the specific location (the entire system, phase B, and phase A). The benefits that can be derived from the use of this algorithm include time, accuracy, speed, which are the requirements for the maintenance of transmission lines. Euclidean distance used in the application of the k-nearest neighbor technique for weights, and K = 3 for number of neighbors. The dataset was split into two parts, 70% training set and 30% testing set.
Jaringan kolaborasi para penulis
7 penulis ·
12 tautan kepenulisan bersama
· 5 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
University of Wasit University of Babylon Al-Qasim Green University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Detection of power transmission lines faults based on voltages and currents values using K-nearest neighbors</dc:title>
<dc:creator>Abed, Nisreen Khalil</dc:creator>
<dc:creator>Abed, Faisal Theyab</dc:creator>
<dc:creator>Al-Yasriy, Hamdalla F.</dc:creator>
<dc:creator>ALRikabi, Haider TH. Salim</dc:creator>
<dc:subject xml:lang="en-US">Faults detection; input features; K-nearest neighbor algorithm; output features; transmission line</dc:subject>
<dc:description xml:lang="en-US">The critical factors to consider when implementing a maintenance plan for energy transmission lines are, accuracy, speed, and time, because of the increased global demand for electricity power caused by rapid development, and overuse of electric power transmission lines (both underground cables and overhead transmission lines), which in turn reduces the efficiency of the lines. Consequently, the efficiency of the lines may be reduced as a result of overuse or other activities like excavation that may have tampered with the cables. Thus, it becomes important to investigate the faults to which the lines are exposed. To this end, this article focuses on the detection of fault in transmission lines through the use of k-nearest neighbor algorithm. Using this algorithm, the characteristics were obtained (voltage, current), and these characteristics enable the identification of faults in the transmission lines, and in the specific location (the entire system, phase B, and phase A). The benefits that can be derived from the use of this algorithm include time, accuracy, speed, which are the requirements for the maintenance of transmission lines. Euclidean distance used in the application of the k-nearest neighbor technique for weights, and K = 3 for number of neighbors. The dataset was split into two parts, 70% training set and 30% testing set.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2023-06-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22547</dc:identifier>
<dc:identifier>10.11591/ijpeds.v14.i2.pp1033-1043</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 2: June 2023; 1033-1043</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v14.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22547/14178</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Nisreen Khalil Abed, Faisal Theyab Abed, Hamdalla F. Al-Yasriy, Haider TH. Salim ALRikabi</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Abed, N. K., Abed, F. T., Al-Yasriy, H. F., & ALRikabi, H. T. S. (2023). Detection of power transmission lines faults based on voltages and currents values using K-nearest neighbors. International Journal of Power Electronics and Drive Systems, 14(2), 1033–1043. https://doi.org/10.11591/ijpeds.v14.i2.pp1033-1043
Salin
IEEE
N. K. Abed, F. T. Abed, H. F. Al-Yasriy, and H. T. S. ALRikabi, “Detection of power transmission lines faults based on voltages and currents values using K-nearest neighbors,” International Journal of Power Electronics and Drive Systems, vol. 14, no. 2, pp. 1033–1043, 2023, doi: 10.11591/ijpeds.v14.i2.pp1033-1043.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.