A fast and robust reference current generation algorithm for three-phase shunt active power filter
International Journal of Power Electronics and Drive Systems · Vol. 12 No. 1 (2021) · hlm. 121–129
ISSN 2722-256X, 2088-8694
Terbit 2021-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The identification of the reference currents constitutes an important part of the control of the active power filter. This part requires an accurate estimation of the frequency, phase, and proper extraction of the load current harmonics. This makes the modeling more difficult and requests a rigorous selection of techniques to be used. For the sake of simplicity, the direct method is motivated by the need for the simplicity and flexibility than the existing techniques such as the instantaneous power theory and diphase currents method. However, this method requires a robust phase-locked loop to extract the unity voltages and a robust controller to estimate the magnitude of the source current. To this end, this paper proposes the hybrid phase-locked loop (HPLL) as a good option mainly because 1) it achieves zero phase error under frequency drifts, 2) Fast dynamic response, 3) totally block the DC offset, 4) From the control point of view, it is a type 1 control system which results in high stability margin. To the best of authors’ knowledge, the HPLL has not been used in active power filter yet. Furthermore, a neural PI regulator is used to estimate the magnitude of the source current. Simulation results show the efficiency of the proposed technique and illustrate all its interesting features. For the sake of comparison, the proposed method is compared to other advanced techniques.
Jaringan kolaborasi para penulis
16 penulis ·
36 tautan kepenulisan bersama
· 19 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Université Djilali de Sidi Bel Abbès Université IBN Khaldoun Tiaret Ahmed Draia University Université de Haute-Alsace Université Ibn Khaldoun Centre National de la Recherche Scientifique Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">A fast and robust reference current generation algorithm for three-phase shunt active power filter</dc:title>
<dc:creator>Chedjara, Zakaria</dc:creator>
<dc:creator>Massoum, Ahmed</dc:creator>
<dc:creator>Wira, Patrice</dc:creator>
<dc:creator>Safa, Ahmed</dc:creator>
<dc:creator>Gouichiche, Abdelmadjid</dc:creator>
<dc:subject xml:lang="en-US">Artificial neural network, Shunt active power filter, Synchronization</dc:subject>
<dc:description xml:lang="en-US">The identification of the reference currents constitutes an important part of the control of the active power filter. This part requires an accurate estimation of the frequency, phase, and proper extraction of the load current harmonics. This makes the modeling more difficult and requests a rigorous selection of techniques to be used. For the sake of simplicity, the direct method is motivated by the need for the simplicity and flexibility than the existing techniques such as the instantaneous power theory and diphase currents method. However, this method requires a robust phase-locked loop to extract the unity voltages and a robust controller to estimate the magnitude of the source current. To this end, this paper proposes the hybrid phase-locked loop (HPLL) as a good option mainly because 1) it achieves zero phase error under frequency drifts, 2) Fast dynamic response, 3) totally block the DC offset, 4) From the control point of view, it is a type 1 control system which results in high stability margin. To the best of authors’ knowledge, the HPLL has not been used in active power filter yet. Furthermore, a neural PI regulator is used to estimate the magnitude of the source current. Simulation results show the efficiency of the proposed technique and illustrate all its interesting features. For the sake of comparison, the proposed method is compared to other advanced techniques.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2021-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20912</dc:identifier>
<dc:identifier>10.11591/ijpeds.v12.i1.pp121-129</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 1: March 2021; 121-129</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v12.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20912/13331</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Zakaria Chedjara, Ahmed Massoum, Patrice Wira, Ahmed Safa, Abdelmadjid Gouichiche</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Chedjara, Z., Massoum, A., Wira, P., Safa, A., & Gouichiche, A. (2021). A fast and robust reference current generation algorithm for three-phase shunt active power filter. International Journal of Power Electronics and Drive Systems, 12(1), 121–129. https://doi.org/10.11591/ijpeds.v12.i1.pp121-129
Salin
IEEE
Z. Chedjara, A. Massoum, P. Wira, A. Safa, and A. Gouichiche, “A fast and robust reference current generation algorithm for three-phase shunt active power filter,” International Journal of Power Electronics and Drive Systems, vol. 12, no. 1, pp. 121–129, 2021, doi: 10.11591/ijpeds.v12.i1.pp121-129.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.