Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimum Renewable Fraction for Grid-connected Photovoltaic in Office Building Energy Systems in Indonesia

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 4 (2018) · hlm. 1866–1874

DOI
10.11591/ijpeds.v9.i4.pp1866-1874
ISSN
2722-256X, 2088-8694
Terbit
2018-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper analyzes influences of renewable fraction on grid-connected photovoltaic (PV) for office building energy systems. The fraction of renewable energy has important contributions on sizing the grid-connected PV systems and selling and buying electricity, and hence reducing net present cost (NPC) and carbon dioxide (CO2) emission. An optimum result with the lowest total NPC for serving an office building is achieved by employing the renewable fraction of 58%, in which 58% of electricity is supplied from the PV and the remaining 42% of electricity is purchased from the grid. The results have shown that the optimum grid-connected PV system with an appropriate renewable fraction value could greatly reduce the total NPC and CO2 emission.

Jaringan kolaborasi para penulis

16 penulis · 41 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tanjungpura University
  • Universiti Sains Malaysia
  • Universitas Muhammadiyah Sumatera Utara
  • Universiti Malaysia Perlis
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Fitriah HusinAfiliasi tidak diketahui8
Syaifurrahman SyaifurrahmanTanjungpura University4
Trias Pontia WigyariantoTanjungpura University3
Yohannes M SimanjuntakTanjungpura University3
Muhammad IrwantoUniversiti Malaysia Perlis2
Suwarno SuwarnoUniversitas Muhammadiyah Sumatera Utara2
Fitriah FitriahTanjungpura University2
Rudy GiantoTanjungpura University1
Mohd HafeezAfiliasi tidak diketahui1
Neilcy Tjahja MooniarsihTanjungpura University1
Syafrudin MasriUniversiti Sains Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Optimum Renewable Fraction for Grid-connected Photovoltaic in Office Building Energy Systems in Indonesia</dc:title>
	<dc:creator>Hiendro, Ayong</dc:creator>
	<dc:creator>Yusuf, Ismail</dc:creator>
	<dc:creator>Pontia Wigyarianto, F. Trias</dc:creator>
	<dc:creator>Hie Khwee, Kho</dc:creator>
	<dc:creator>Junaidi, Junaidi</dc:creator>
	<dc:description xml:lang="en-US">This paper analyzes influences of renewable fraction on grid-connected photovoltaic (PV) for office building energy systems. The fraction of renewable energy has important contributions on sizing the grid-connected PV systems and selling and buying electricity, and hence reducing net present cost (NPC) and carbon dioxide (CO2) emission. An optimum result with the lowest total NPC for serving an office building is achieved by employing the renewable fraction of 58%, in which 58% of electricity is supplied from the PV and the remaining 42% of electricity is purchased from the grid. The results have shown that the optimum grid-connected PV system with an appropriate renewable fraction value could greatly reduce the total NPC and CO2 emission.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/13950</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i4.pp1866-1874</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 4: December 2018; 1866-1874</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/13950/11499</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Ayong Hiendro, Ismail Yusuf, F. Trias Pontia Wigyarianto, Kho Hie Khwee, Junaidi Junaidi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>