Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Fault-tolerant control with high-order sliding mode for manipulator robot

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 3 (2022) · hlm. 1854–1869

DOI
10.11591/ijpeds.v13.i3.pp1854-1869
ISSN
2722-256X, 2088-8694
Terbit
2022-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The safety of manipulators systems is receiving a lot of attention these days. Faults have the ability to carry out harmful activities that harm equipment, the environment, or persons. As a result, it is critical to detect and diagnose problems as soon as possible, as well as to incorporate fault tolerance to avoid performance deterioration and harmful circumstances. Robust sensor fault detection and isolation (FDI) as well as fault-tolerant control (FTC) for a robotic system are discussed in this work. The goal of this research is to create an FDI method that uses a super-twisting third-order sliding mode (STW-TOSM) observer to estimate residual signals. A suggested system based on a higher-order sliding mode (HOSM) observer/controller approaches is used to accomplish this. In comparison to an active FTC technique, the test results demonstrate high level of performance. Finally, simulation results illustrate the efficacy of the presented techniques.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 18 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sidi Mohamed Ben Abdellah University
  • Mohammed V University
  • Université Ibn-Tofail
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Asmae HafianSidi Mohamed Ben Abdellah University4
Nassima JihaniSidi Mohamed Ben Abdellah University2
Imane AbziSidi Mohamed Ben Abdellah University2
Imane CheikhSidi Mohamed Ben Abdellah University2
Hachmia FaqihiUniversité Ibn-Tofail2
Mohammed BenbrahimSidi Mohamed Ben Abdellah University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Fault-tolerant control with high-order sliding mode for manipulator robot</dc:title>
	<dc:creator>Omali, Khaoula Oulidi</dc:creator>
	<dc:creator>Kabbaj, Mohammed Nabil</dc:creator>
	<dc:creator>Benbrahim, Mohammed</dc:creator>
	<dc:subject xml:lang="en-US">Fault detection; Fault-tolerant control; Higher order sliding mode; Robotic</dc:subject>
	<dc:description xml:lang="en-US">The safety of manipulators systems is receiving a lot of attention these days. Faults have the ability to carry out harmful activities that harm equipment, the environment, or persons. As a result, it is critical to detect and diagnose problems as soon as possible, as well as to incorporate fault tolerance to avoid performance deterioration and harmful circumstances. Robust sensor fault detection and isolation (FDI) as well as fault-tolerant control (FTC) for a robotic system are discussed in this work. The goal of this research is to create an FDI method that uses a super-twisting third-order sliding mode (STW-TOSM) observer to estimate residual signals. A suggested system based on a higher-order sliding mode (HOSM) observer/controller approaches is used to accomplish this. In comparison to an active FTC technique, the test results demonstrate high level of performance. Finally, simulation results illustrate the efficacy of the presented techniques.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21245</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i3.pp1854-1869</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 3: September 2022; 1854-1869</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21245/13933</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Khaoula Oulidi Omali, Mohammed Nabil Kabbaj, Mohammed Benbrahim</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>