Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Time response of FOPID controlled PV based cascaded landsman converter-inverter fed induction motor and electric drives applications

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 3 (2020) · hlm. 1379–1387

DOI
10.11591/ijpeds.v11.i3.pp1379-1387
ISSN
2722-256X, 2088-8694
Terbit
2020-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Time Response enhancement utilizing photovoltaic based cascaded Landsman Converter (LC) structure is one of the soft strategies in the recent scenario. The prime function of a DC-DC Landsman converter is to optimize the output power of the photovoltaic array and reduce the output voltage ripples. This paper reveals the demonstration and simulation of the Cascaded Landsman Converter Inverter System (CLCIS) with a PV source. MATLAB Simulink-model for CLCIS has been created utilizing the components of Simulink and closed-loop examinations are performed with PI and Fractional-Order-PID (FOPID) Controllers. The present work deal with the comparison of transient and steady-state time responses of CLCIS with PI and FOPID controllers. The outcomes demonstrate that dynamic reaction is enhanced by utilizing FOPID controller.

Jaringan kolaborasi para penulis

17 penulis · 28 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Annamalai University
  • Karpagam Academy of Higher Education
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S.P. NatarajanAnnamalai University3
Ponnusamy VijayakumarKarpagam Academy of Higher Education2
T. S. AnandhiAnnamalai University2
B. ShanthiAnnamalai University2
T. SengolrajanKarpagam Academy of Higher Education1
V. PadmathilagamAnnamalai University1
A.N. AbiramiAfiliasi tidak diketahui1
D. MeenaAfiliasi tidak diketahui1
K. VijayalakshmiKarpagam Academy of Higher Education1
A. Clement RajAnnamalai University1
S. M. RevathyAfiliasi tidak diketahui1
K. Ramash KumarKarpagam Academy of Higher Education1
Arvind ThirumalaiKarpagam Academy of Higher Education1
T.S. AnandhiAnnamalai University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Time response of FOPID controlled PV based cascaded landsman converter-inverter fed induction motor and electric drives applications</dc:title>
	<dc:creator>Pazhanimurugan, R.</dc:creator>
	<dc:creator>Bensraj, R.</dc:creator>
	<dc:creator>Balamurugan, C.R.</dc:creator>
	<dc:description xml:lang="en-US">Time Response enhancement utilizing photovoltaic based cascaded Landsman Converter (LC) structure is one of the soft strategies in the recent scenario. The prime function of a DC-DC Landsman converter is to optimize the output power of the photovoltaic array and reduce the output voltage ripples. This paper reveals the demonstration and simulation of the Cascaded Landsman Converter Inverter System (CLCIS) with a PV source. MATLAB Simulink-model for CLCIS has been created utilizing the components of Simulink and closed-loop examinations are performed with PI and Fractional-Order-PID (FOPID) Controllers. The present work deal with the comparison of transient and steady-state time responses of CLCIS with PI and FOPID controllers. The outcomes demonstrate that dynamic reaction is enhanced by utilizing FOPID controller.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20445</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1379-1387</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1379-1387</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20445/13186</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 R. Pazhanimurugan, R. Bensraj, C.R. Balamurugan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>