Akses terbuka
Jurnal
SINTA 1
Single-phase five level modified neutral point clamped grid connected inverter topology with front-end chopper control of DC-link capacitor voltages
International Journal of Power Electronics and Drive Systems · Vol. 15 No. 4 (2024) · hlm. 2287–2295
ISSN 2722-256X, 2088-8694
Terbit 2024-12-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
Conventionally, only the standalone operation of a single-phase fault tolerant-based 5-level neutral point clamped (SPFT-5L-NPC) inverter with two stiff DC sources has been explained with consideration of phase disposition pulse width modulation (PD-PWM) technique. In this topology, the bidirectional switch arrangement consists of four diodes and one IGBT switch. This arrangement inherently increases conduction losses of topology. Generally, any NPC inverter topology suffers from a DC-link capacitor voltage (DCL-CV) balancing issue. In the conventional contribution of work, authors have not discussed the front-end voltage balancing issue. This study describes the extension work of a single-phase grid connection with a modified 5L-NPC (M5L-NPC) inverter topology, taking into account the aforementioned concerns. In this topology, the simple front-end chopper circuit has been utilized to balance the DCL-CVs and to reduce conduction losses, another arrangement of bidirectional switch has been utilized. In this paper, both standalone and grid connections of M5L-NPC topology have been explained along with control of DCL-CVs. The grid-connected important objectives of active power control (APC), reactive power control (RPC), and injecting sinusoidal current with low harmonic distortion have been discussed thoroughly considering a simple control strategy.
Jaringan kolaborasi para penulis
6 penulis ·
7 tautan kepenulisan bersama
· 4 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Osmania University Chaitanya Bharathi Institute of Technology Chaitanya
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Single-phase five level modified neutral point clamped grid connected inverter topology with front-end chopper control of DC-link capacitor voltages</dc:title>
<dc:creator>Kumar, Y. Sravan</dc:creator>
<dc:creator>Krishna, T. Murali</dc:creator>
<dc:creator>Guduri, Yesuratnam</dc:creator>
<dc:subject xml:lang="en-US">Active power control; grid-connected inverter; low harmonic distortion; pulse width modulation; reactive power control</dc:subject>
<dc:description xml:lang="en-US">Conventionally, only the standalone operation of a single-phase fault tolerant-based 5-level neutral point clamped (SPFT-5L-NPC) inverter with two stiff DC sources has been explained with consideration of phase disposition pulse width modulation (PD-PWM) technique. In this topology, the bidirectional switch arrangement consists of four diodes and one IGBT switch. This arrangement inherently increases conduction losses of topology. Generally, any NPC inverter topology suffers from a DC-link capacitor voltage (DCL-CV) balancing issue. In the conventional contribution of work, authors have not discussed the front-end voltage balancing issue. This study describes the extension work of a single-phase grid connection with a modified 5L-NPC (M5L-NPC) inverter topology, taking into account the aforementioned concerns. In this topology, the simple front-end chopper circuit has been utilized to balance the DCL-CVs and to reduce conduction losses, another arrangement of bidirectional switch has been utilized. In this paper, both standalone and grid connections of M5L-NPC topology have been explained along with control of DCL-CVs. The grid-connected important objectives of active power control (APC), reactive power control (RPC), and injecting sinusoidal current with low harmonic distortion have been discussed thoroughly considering a simple control strategy.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2024-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23353</dc:identifier>
<dc:identifier>10.11591/ijpeds.v15.i4.pp2287-2295</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 4: December 2024; 2287-2295</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v15.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23353/14796</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2024 Sravan Kumar Yenagandula, Murali Krishna T, Yesuratnam G</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Kumar, Y. S., Krishna, T. M., & Guduri, Y. (2024). Single-phase five level modified neutral point clamped grid connected inverter topology with front-end chopper control of DC-link capacitor voltages. International Journal of Power Electronics and Drive Systems, 15(4), 2287–2295. https://doi.org/10.11591/ijpeds.v15.i4.pp2287-2295
Salin
IEEE
Y. S. Kumar, T. M. Krishna, and Y. Guduri, “Single-phase five level modified neutral point clamped grid connected inverter topology with front-end chopper control of DC-link capacitor voltages,” International Journal of Power Electronics and Drive Systems, vol. 15, no. 4, pp. 2287–2295, 2024, doi: 10.11591/ijpeds.v15.i4.pp2287-2295.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.