In AC/DC hybrid micro grid system (HMGS) power converters are always tested for is performance in distribution, its ability to provide accurate power sharing, transient stability and load dynamics. The existing control methods either complex or limited to achieve optimal power flow. This paper proposes a modified decentralized droop control scheme for interlinking converter (ILC) connected to interconnected AC and DC grids. A three coordinated model is proposed where AC frequency, ILC power and DC voltage are corresponding axis. The power sharing through the ILC is dependent on the AC frequency droop and DC voltage droop which occurs due to overloading. The control scheme is designed for single and three phases ILC. The obtained results are compared with double loop control method which shows less frequency deviations, accurate power sharing. The ILC performs autonomously and transfer power bidirectional under islanded mode. The simulation is carried in MATLAB/Simulink.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 11 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology
  • Mepco Schlenk Engineering College
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Chithras ThangavelVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology1
Vinoth KrishnamoorthyVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology1
Jawahar MarimuthuMepco Schlenk Engineering College1
Edward Rajan Samuel NadarMepco Schlenk Engineering College1
Karthik Kumar KMepco Schlenk Engineering College1
Vanam SatyanarayanaVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Inter-connected AC/DC HMGS power management with  3-phase and 1-phase ILC</dc:title>
	<dc:creator>Razzaq, Syed Abdul</dc:creator>
	<dc:creator>Jayasankar, Vairavasamy</dc:creator>
	<dc:subject xml:lang="en-US">BESS; Droop control; HMGS; ILC; Inter-connected</dc:subject>
	<dc:description xml:lang="en-US">In AC/DC hybrid micro grid system (HMGS) power converters are always tested for is performance in distribution, its ability to provide accurate power sharing, transient stability and load dynamics. The existing control methods either complex or limited to achieve optimal power flow. This paper proposes a modified decentralized droop control scheme for interlinking converter (ILC) connected to interconnected AC and DC grids. A three coordinated model is proposed where AC frequency, ILC power and DC voltage are corresponding axis. The power sharing through the ILC is dependent on the AC frequency droop and DC voltage droop which occurs due to overloading. The control scheme is designed for single and three phases ILC. The obtained results are compared with double loop control method which shows less frequency deviations, accurate power sharing. The ILC performs autonomously and transfer power bidirectional under islanded mode. The simulation is carried in MATLAB/Simulink.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">None</dc:contributor>
	<dc:date>2023-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22114</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v14.i1.pp311-319</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 14, No 1: March 2023; 311-319</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v14.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22114/14086</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Syed Abdul Razzaq, Vairavasamy Jayasankar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>