Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Control Design For Shunt Active Power Filter Based On p-q Theory In Photovoltaic Grid-Connected System

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 3 (2018) · hlm. 1064–1071

DOI
10.11591/ijpeds.v9.i3.pp1064-1071
ISSN
2722-256X, 2088-8694
Terbit
2018-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents the control for Shunt Active Power (SAPF) filter in photovoltaic (PV) systems connected to the grid. The proposed configuration of the system consists of a photovoltaic array that connected to the grid through the three-phase inverter topology that also serves as an active filter. Photovoltaic is coupled in parallel with the direct curret (DC) side of the active filter. With this configuration, can be obtained three advantages, namely the elimination of harmonic currents caused by nonlinear load, reactive power injection, and injection of active power generated photovoltaic. The p-q Theory is used to calculate the harmonic reference current to be used to control the active filter coupled fotovoltaic in generating anti-harmonic currents. The results show that system can reduce harmonic distortion from THD 27.22% to be THD 1.05%, whereas when the active power from photovoltaic injected, the THD become 2.01%. Power sharing can also be seen from this study.

Jaringan kolaborasi para penulis

10 penulis · 15 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Politeknik Negeri Madura
  • Politeknik Negeri Semarang
  • Telkom University
  • Minia University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammad NurPoliteknik Negeri Madura1
Kukuh WidarsonoPoliteknik Negeri Madura1
Adi SoeprijantoInstitut Teknologi Sepuluh Nopember1
Dwiana HendrawatiPoliteknik Negeri Semarang1
Adel A. ElbasetMinia University1
Heri SuryoatmojoInstitut Teknologi Sepuluh Nopember1
Alwy Muhammad RaviTelkom University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Control Design For Shunt Active Power Filter Based On  p-q Theory In Photovoltaic Grid-Connected System</dc:title>
	<dc:creator>Jauhari, Moh.</dc:creator>
	<dc:creator>Riawan, Dedet Candra</dc:creator>
	<dc:creator>Ashari, Mochamad</dc:creator>
	<dc:description xml:lang="en-US">This paper presents the control for Shunt Active Power (SAPF) filter in photovoltaic (PV) systems connected to the grid. The proposed configuration of the system consists of a photovoltaic array that connected to the grid through the three-phase inverter topology that also serves as an active filter. Photovoltaic is coupled in parallel with the direct curret (DC) side of the active filter. With this configuration, can be obtained three advantages, namely the elimination of harmonic currents caused by nonlinear load, reactive power injection, and injection of active power generated photovoltaic. The p-q Theory is used to calculate the harmonic reference current to be used to control the active filter coupled fotovoltaic in generating anti-harmonic currents. The results show that system can reduce harmonic distortion from THD 27.22% to be THD 1.05%, whereas when the active power from photovoltaic injected, the THD become 2.01%. Power sharing can also be seen from this study.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11325</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i3.pp1064-1071</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 3: September 2018; 1064-1071</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/11325/11302</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Moh. Jauhari, Dedet Candra Riawan, Mochamad Ashari</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>