Enhancing performance of grid-connected photovoltaic systems based on three-phase five-level cascaded inverter

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 4 (2021) · hlm. 2295–2304

DOI
10.11591/ijpeds.v12.i4.pp2295-2304
ISSN
2722-256X, 2088-8694
Terbit
2021-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Multilevel inverters play an important role in power converters due to their good advantages. The cascaded H-bridge inverter is one of the most prominent and most suitable multilevel inverters in PV systems. Each H-bridge has a separate photovoltaic (PV) array as an independent direct current (DC) source. This paper introduces a three-phase cascaded H-bridge inverter with five levels connected to the grid to improve the performance and efficiency of the photovoltaic system. In the proposed system, each PV group has MPPT to extract the maximum power point from the PV group at certain irradiation and temperature and also to mitigate the mismatch that causes in the imbalance transmitted power from inverter to the main grid. The proposed control scheme with modulation compensation was used, and the system was simulated in MATLAB/Simulink with two different scenarios. The simulation results demonstrate the effectiveness of the proposed connection in minimizing the total harmonic distortion (THD) to acceptable limit, low overshoot, and fast-tracking to the desired value.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 21 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology - Iraq
  • Alsalam University College
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Oday Ali AhmedUniversity of Technology - Iraq3
Waleed H. HabeebUniversity of Technology - Iraq3
Kanaan A. JalalUniversity of Technology - Iraq3
Hussain SayedUniversity of Technology - Iraq3
Marwan Saded AhmedAfiliasi tidak diketahui2
Shaimaa A. HusseinAfiliasi tidak diketahui2
Zahraa Salman DawoodAfiliasi tidak diketahui1
Hashim Abed HusseinAfiliasi tidak diketahui1
Ashwaq Qasim HameedAlsalam University College1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Enhancing performance of grid-connected photovoltaic systems based on three-phase five-level cascaded inverter</dc:title>
	<dc:creator>Ahmad, Marwan E.</dc:creator>
	<dc:creator>Numan, Ali. H.</dc:creator>
	<dc:creator>Mahmood, Dhari Y.</dc:creator>
	<dc:subject xml:lang="en-US">Cascaded H-bridge inverters; Grid-connected PV systems; Photovoltaic panels mismatch; Maximum power point tracking; Multilevel modulations compensation</dc:subject>
	<dc:description xml:lang="en-US">Multilevel inverters play an important role in power converters due to their good advantages. The cascaded H-bridge inverter is one of the most prominent and most suitable multilevel inverters in PV systems. Each H-bridge has a separate photovoltaic (PV) array as an independent direct current (DC) source. This paper introduces a three-phase cascaded H-bridge inverter with five levels connected to the grid to improve the performance and efficiency of the photovoltaic system. In the proposed system, each PV group has MPPT to extract the maximum power point from the PV group at certain irradiation and temperature and also to mitigate the mismatch that causes in the imbalance transmitted power from inverter to the main grid. The proposed control scheme with modulation compensation was used, and the system was simulated in MATLAB/Simulink with two different scenarios. The simulation results demonstrate the effectiveness of the proposed connection in minimizing the total harmonic distortion (THD) to acceptable limit, low overshoot, and fast-tracking to the desired value.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21508</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i4.pp2295-2304</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 4: December 2021; 2295-2304</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21508/13575</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Marwan E. Ahmad, Ali. H. Numan, Dhari Y. Mahmood</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>