Abstrak

This paper compares the magnetic, electrical, and mechanical characteristics of two permanent magnet generator topologies: single-gap axial flux and single-gap inner rotor radial flux. The study aims to identify how the key parameters fluctuate at each power capacity and investigate the trends in their values as power changes. The power capacities observed are 300 W, 600 W, 900 W, 1200 W, and 1500 W. Simulations used with the help of Ansys Maxwell software to obtain: i) magnetic characteristics without load, including air gap flux density, flux linkage, and induced voltage, ii) electrical performance, consisting of armature current, terminal voltage, voltage regulation, total harmonic distortion, core loss and output power, and iii) mechanical performance, including shaft torque and cogging torque. The last step compares the power density of both topologies. The simulation results show that the axial flux permanent magnet generator (AFPMG) has better air gap flux density, voltage regulation, total harmonic distortion (THD), efficiency, electromagnetic torque, and power density characteristics. Meanwhile, the radial flux permanent magnet generator (RFPMG) is superior in induced voltage and output power. These results conclude that, in general, AFPMG is exceptional from a technical point of view and is more economical when applied to hydro or wind energy systems.

Kata kunci

Jaringan kolaborasi para penulis

36 penulis · 134 tautan kepenulisan bersama · 79 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Research and Innovation Agency
  • Indonesian Institute of Sciences
  • Bandung Institute of Technology
  • Diponegoro University
  • National University of Malaysia
  • Universitas Widyatama
  • Telkom University
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Pekik Argo DahonoBandung Institute of Technology5
Harjono Priyo SantosaNational Research and Innovation Agency4
Ersalina Werda MuktiIndonesian Institute of Sciences4
Gifari Iswandi HasyimBandung Institute of Technology3
Jihad FurqaniBandung Institute of Technology3
Arwindra RizqiawanBandung Institute of Technology3
Agus RisdiyantoNational Research and Innovation Agency3
Noviadi Arief RachmanIndonesian Institute of Sciences3
Muhammad Fathul HikmawanNational Research and Innovation Agency3
Tajuddin NurAtma Jaya Catholic University of Indonesia3
I Nengah DiastaBandung Institute of Technology3
Priyono SoetiknoBandung Institute of Technology3
Yugo KumoroIndonesian Institute of Sciences2
Yuliana SusilowatiIndonesian Institute of Sciences2
Wawan Hendriawan NurIndonesian Institute of Sciences2
Yunarto YunartoIndonesian Institute of Sciences2
Bambang SusantoIndonesian Institute of Sciences2
Priyono SutiknoBandung Institute of Technology2
Qidun MaulanaIndonesian Institute of Sciences2
Ahmad FudholiNational University of Malaysia2
Ant. Ardath KristiNational Research and Innovation Agency2
Agus JunaediNational Research and Innovation Agency2
Indrarini Dyah IrawatiTelkom University2
Budi AzhariIndonesian Institute of Sciences2
Rudi DarussalamNational Research and Innovation Agency1
Dalmasius Ganjar SubagioIndonesian Institute of Sciences1
Udin KomarudinUniversitas Widyatama1
Qidun Maulana Binu SoesantoDiponegoro University1
Qidir Maulana Binu SoesantoDiponegoro University1
Tinton Dwi AtmajaNational Research and Innovation Agency1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Permanent magnet generator performance comparison under different topologies and capacities</dc:title>
	<dc:creator>Wirtayasa, Ketut</dc:creator>
	<dc:creator>Kasim, Muhammad</dc:creator>
	<dc:creator>Widiyanto, Puji</dc:creator>
	<dc:creator>Muqorobin, Anwar</dc:creator>
	<dc:creator>Wijanarko, Sulistyo</dc:creator>
	<dc:creator>Irasari, Pudji</dc:creator>
	<dc:subject xml:lang="en-US">Ansys Maxwell; axial flux permanent magnet generator; electrical performance; mechanical performance; radial flux permanent magnet generator</dc:subject>
	<dc:description xml:lang="en-US">This paper compares the magnetic, electrical, and mechanical characteristics of two permanent magnet generator topologies: single-gap axial flux and single-gap inner rotor radial flux. The study aims to identify how the key parameters fluctuate at each power capacity and investigate the trends in their values as power changes. The power capacities observed are 300 W, 600 W, 900 W, 1200 W, and 1500 W. Simulations used with the help of Ansys Maxwell software to obtain: i) magnetic characteristics without load, including air gap flux density, flux linkage, and induced voltage, ii) electrical performance, consisting of armature current, terminal voltage, voltage regulation, total harmonic distortion, core loss and output power, and iii) mechanical performance, including shaft torque and cogging torque. The last step compares the power density of both topologies. The simulation results show that the axial flux permanent magnet generator (AFPMG) has better air gap flux density, voltage regulation, total harmonic distortion (THD), efficiency, electromagnetic torque, and power density characteristics. Meanwhile, the radial flux permanent magnet generator (RFPMG) is superior in induced voltage and output power. These results conclude that, in general, AFPMG is exceptional from a technical point of view and is more economical when applied to hydro or wind energy systems.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23922</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i3.pp1516-1527</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 3: September 2025; 1516-1527</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23922/14991</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Ketut Wirtayasa, Muhammad Kasim, Puji Widiyanto, Anwar Muqorobin, Sulistyo Wijanarko, Pudji Irasari</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>