Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Speed Sensorless Control of IM Drives

International Journal of Power Electronics and Drive Systems · Vol. 4 No. 1 (2014) · hlm. 81–90

ISSN
2722-256X, 2088-8694
Terbit
2014-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper investigates the performance of a Model reference adaptive system (MRAS) based cost-effective drive system of an induction motor (IM) for low-cost applications - high performance industrial drive systems. In this paper, the MRAS is used as a speed estimator and the motor is fed from a four-switch three-phase (FSTP) inverter instead of a conventional six-switch three-phase (SSTP) inverter. This configuration reduces the cost of the inverter, the switching losses, and the complexity of the control algorithms and interface circuits, the proposed control approach reduces the computation for real-time implementation.. The robustness of the proposed MRAS-based FSTP inverter fed IM drive is verified by Experimental results at different operating conditions using digital signal processor (DSP1103) for a 1.1 Kw motor. A performance comparison of the proposed FSTP inverter fed IM drive with a conventional SSTP inverter system is also made in terms of speed response and total harmonic distortion (THD) of the stator current. The proposed FSTP inverter fed IM drive is found quite acceptable considering its performance, cost reduction and other advantages features.DOI: http://dx.doi.org/10.11591/ijpeds.v4i1.5036

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Haitham Zaki AzaziAfiliasi tidak diketahui1
Z. M. El-BarbaryAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Total Harmonic Distortion Analysis of a Four Switch 3-Phase Inverter Fed Speed Sensorless Control of  IM Drives</dc:title>
	<dc:creator>El-Barbary, Zakaria M.S.</dc:creator>
	<dc:creator>Azazi, H. Z.</dc:creator>
	<dc:creator>Metwally, M. K.</dc:creator>
	<dc:description xml:lang="en-US">This paper investigates the performance of a Model reference adaptive system (MRAS) based cost-effective drive system of an induction motor (IM) for low-cost applications - high performance industrial drive systems . In this paper, the MRAS is used as a speed estimator and the motor is fed from a four-switch three-phase (FSTP) inverter instead of a conventional six-switch three-phase (SSTP) inverter. This configuration reduces the cost of the inverter, the switching losses, and the complexity of the control algorithms and interface circuits, the proposed control approach reduces the computation for real-time implementation.. The robustness of the proposed MRAS-based FSTP inverter fed IM drive is verified by Experimental results at different operating conditions using digital signal processor (DSP1103) for a 1.1 Kw motor. A performance comparison of the proposed FSTP inverter fed IM drive with a conventional SSTP inverter system is also made in terms of speed response and total harmonic distortion (THD) of the stator current. The proposed FSTP inverter fed IM drive is found quite acceptable considering its performance, cost reduction and other advantages features.DOI: http://dx.doi.org/10.11591/ijpeds.v4i1.5036</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2014-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4981</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 4, No 1: March 2014; 81-90</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v4.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4981/4976</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2014 Zakaria M.S. El-Barbary, H. Z. Azazi, M. K. Metwally</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>