Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance improvement of harmonic detection algorithm in three phase three wire shunt active power filter under balance voltage condition

International Journal of Power Electronics and Drive Systems · Vol. 16 No. 1 (2025) · hlm. 380–388

DOI
10.11591/ijpeds.v16.i1.pp380-388
ISSN
2722-256X, 2088-8694
Terbit
2025-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Effective harmonic current identification is critical for shunt active power filters (SAPF) to provide accurate and sufficient compensation. This study proposes a modified synchronous reference frame fundamental (MSRFF) method for harmonic extraction in three-phase, three-wire systems. A band pass filter (BPF) was designed by combining low-pass and high-pass filters in the direct-quadrature (d-q) reference frame to improve filtering performance. Unlike traditional methods using phase-locked loops (PLL), this approach employs unit vector templates for synchronization and relies on direct current measurements from load currents. The band pass filter, with low cutoff frequencies, effectively isolates harmonic components in heavily contaminated systems, outperforming other filtering methods. System performance was evaluated using matrix laboratory (MATLAB) simulations, where total harmonic distortion (THD) values were reduced to 2.19% with a low pass filter, 0.99% with a conventional band pass filter, and 0.98% with the combined filter approach. The results demonstrate that the proposed strategy can accurately track and estimate harmonic signals, offering a robust solution for shunt active power filter applications.

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 72 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • Kaduna Polytechnic
  • Universiti Teknikal Malaysia Melaka
  • University of Kuala Lumpur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Pusparini Dewi Abd AzizUniversity of Kuala Lumpur5
Muhammad Murtadha OthmanUniversiti Teknologi MARA4
Ayman Nurshazwan Abdul RashidAfiliasi tidak diketahui3
Zuhaila Mat YasinUniversiti Teknologi MARA2
Faranadia Abdul HarisUniversiti Teknologi MARA2
Nur Syafiqah Mohd TaibUniversiti Teknologi MARA2
Nofri Yenita DahlanUniversiti Teknologi MARA1
Elia Erwani HassanUniversiti Teknikal Malaysia Melaka1
Nur Syifa Nasyrah RazaliUniversiti Teknologi MARA1
Nurfadzilah AhmadUniversiti Teknologi MARA1
Ismail MusirinUniversiti Teknologi MARA1
Muhammad Alif MansorUniversiti Teknologi MARA1
N. AminudinUniversiti Teknologi MARA1
N. RosmiziUniversiti Teknologi MARA1
Nur Ashida SalimUniversiti Teknologi MARA1
Hasmaini MohamadUniversiti Teknologi MARA1
Mohammad Shariful IslamUniversiti Teknologi MARA1
Khairul Safuan MuhammadUniversiti Teknologi MARA1
Fajariah KadirUniversiti Teknologi MARA1
A. RaziUniversiti Teknikal Malaysia Melaka1
Mohammad Nawawi SerojiUniversiti Teknologi MARA1
Muhamad Nabil Bin HidayatUniversiti Teknologi MARA1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance improvement of harmonic detection algorithm in three phase three wire shunt active power filter under balance voltage condition</dc:title>
	<dc:creator>Usman, Zubairu</dc:creator>
	<dc:creator>Azmi, Muhammad Hasbi</dc:creator>
	<dc:creator>Mohammad Noor, Siti Zaliha</dc:creator>
	<dc:creator>Musa, Suleiman</dc:creator>
	<dc:subject xml:lang="en-US">active power filter; band pass filter; D-Q theory; high pass filter; low pass filter; total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">Effective harmonic current identification is critical for shunt active power filters (SAPF) to provide accurate and sufficient compensation. This study proposes a modified synchronous reference frame fundamental (MSRFF) method for harmonic extraction in three-phase, three-wire systems. A band pass filter (BPF) was designed by combining low-pass and high-pass filters in the direct-quadrature (d-q) reference frame to improve filtering performance. Unlike traditional methods using phase-locked loops (PLL), this approach employs unit vector templates for synchronization and relies on direct current measurements from load currents. The band pass filter, with low cutoff frequencies, effectively isolates harmonic components in heavily contaminated systems, outperforming other filtering methods. System performance was evaluated using matrix laboratory (MATLAB) simulations, where total harmonic distortion (THD) values were reduced to 2.19% with a low pass filter, 0.99% with a conventional band pass filter, and 0.98% with the combined filter approach. The results demonstrate that the proposed strategy can accurately track and estimate harmonic signals, offering a robust solution for shunt active power filter applications.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23349</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v16.i1.pp380-388</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 1: March 2025; 380-388</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v16.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23349/14862</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Siti Zaliha Mohammad Noor, Suleiman Musa, Zubairu Usman</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>