Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 3 (2020) · hlm. 1430–1440

DOI
10.11591/ijpeds.v11.i3.pp1430-1440
ISSN
2722-256X, 2088-8694
Terbit
2020-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less power devices requirement and simple design. MLI CHB is also capable to produce possible output voltage at twice of the number of DC source which in this case of APF is the best suited topology to replace with the conventional six -step inverter. This paper presents the performance of three- phase three-wire CHB MLI used in Shunt Active Power Filter (SAPF) based on Direct Current Control (DCC) and Indirect Current Control (ICC) schemes. Both schemes are developed and verified in MATLAB/Simulink. The simulation results show that both current control algorithms are capable to mitigate load current with Total Harmonic Distortion below than the permissible value based on IEEE 519 standard.

Jaringan kolaborasi para penulis

40 penulis · 139 tautan kepenulisan bersama · 51 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Putra Malaysia
  • Universitas Ahmad Dahlan
  • University of Technology Malaysia
  • Universiti Malaysia Perlis
  • UNSW Sydney
  • Tun Hussein Onn University of Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tole SutiknoUniversitas Ahmad Dahlan39
Kasrul Abdul KarimUniversiti Teknikal Malaysia Melaka18
Siti Azura Ahmad TarusanUniversiti Teknikal Malaysia Melaka11
Mohd Luqman Mohd Jamil‬Universiti Teknikal Malaysia Melaka8
Maaspaliza AzriUniversiti Teknikal Malaysia Melaka7
Nor Azizah Mohd YusoffUniversiti Teknikal Malaysia Melaka6
Nik Rumzi Nik IdrisUniversity of Technology Malaysia5
Azziddin Mohamad RazaliUniversiti Teknikal Malaysia Melaka5
Raja Nor Firdaus Kashfi Raja OthmanUniversiti Teknikal Malaysia Melaka5
Nurfaezah AbdullahUniversiti Teknikal Malaysia Melaka4
Muhammad Zaid AihsanUniversiti Malaysia Perlis4
Aiman Zakwan JidinUniversiti Teknikal Malaysia Melaka3
S. FarinaUniversiti Teknikal Malaysia Melaka3
R. N. FirdausUniversiti Teknikal Malaysia Melaka3
Md Hairul Nizam TalibUniversiti Teknikal Malaysia Melaka3
Zulhani RasinUniversiti Teknikal Malaysia Melaka3
T. C. KwangUniversiti Teknikal Malaysia Melaka2
Zuraidi Md TahirUniversiti Teknikal Malaysia Melaka2
Mohammad Lutfi OthmanUniversiti Putra Malaysia2
F. AzharUniversiti Teknikal Malaysia Melaka2
Mohd Saufi AhmadUniversiti Teknikal Malaysia Melaka2
R. SuhairiUniversiti Teknikal Malaysia Melaka2
Mohd Hatta JopriUniversiti Teknikal Malaysia Melaka2
Mohd Khair HassanUniversiti Putra Malaysia2
Yusnida Ahmad TarmiziUniversiti Teknikal Malaysia Melaka2
Nik Rumzi Nik IdrisAfiliasi tidak diketahui2
Muhammed Fazlur RahmanUNSW Sydney2
Azrita binti AliasUniversiti Teknikal Malaysia Melaka2
Syed Abrar Syed Ahmad ZawawiUniversiti Teknikal Malaysia Melaka2
Nurul Syahada Muhamad SabriUniversiti Teknikal Malaysia Melaka2
Muhamad Faizal YaakubUniversiti Teknikal Malaysia Melaka2
Faridah Hanim Mohd NohTun Hussein Onn University of Malaysia2
Norman MariunUniversiti Putra Malaysia2
Mohamad Haireen Bin FatheliUniversiti Teknikal Malaysia Melaka1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Performance of three-phase three-wire cascaded H-bridge multilevel inverter-based shunt active power filter</dc:title>
	<dc:creator>Yusup Lada, Musa</dc:creator>
	<dc:creator>Mohd Radzi, Mohd Amran</dc:creator>
	<dc:creator>Jasni, Jasronita</dc:creator>
	<dc:creator>Hizam, Hashim</dc:creator>
	<dc:creator>Jidin, Auzani</dc:creator>
	<dc:creator>Mohamad, Syahrul Hisham</dc:creator>
	<dc:description xml:lang="en-US">Multilevel inverter (MLI) becomes more significant in Active Power Filter (APF) application due to capability to its produce low harmonic output current in which at the same time improving performance of APF. Among the topologies of MLI, Cascaded H-Bridge (CHB) is the most popular topology with less power devices requirement and simple design. MLI CHB is also capable to produce possible output voltage at twice of the number of DC source which in this case of APF is the best suited topology to replace with the conventional six -step inverter. This paper presents the performance of three- phase three-wire CHB MLI used in Shunt Active Power Filter (SAPF) based on Direct Current Control (DCC) and Indirect Current Control (ICC) schemes. Both schemes are developed and verified in MATLAB/Simulink. The simulation results show that both current control algorithms are capable to mitigate load current with Total Harmonic Distortion below than the permissible value based on IEEE 519 standard.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Universiti Putra Malaysia, Faculty of Engineering</dc:contributor>
	<dc:contributor xml:lang="en-US">Universiti Teknikal Malaysia Melaka, Faculty of Electrical Engineering</dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20677</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1430-1440</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1430-1440</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20677/13232</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Musa Yusup Lada, Mohd Amran Mohd Radzi, Jasronita Jasni, Hashim Hizam, Auzani Jidin, Syahrul Hisham Mohamad</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>