Abstrak

Selective harmonic elimination technique SHE is adopted in this work to reduce the harmonic contents in single phase cascaded multilevel inverter. The firing instants for the electronic switches MOSFETs in the inverter are calculated off line for five level to thirteen level inverter. An Arduino microcontroller is programmed to cope with different topologies of the multilevel inverter. The implemented multi-level (MLI) inverter results are compared with Simulink simulation program and are found very close to each other. SHE technique works at system frequency (50 Hz or 60 Hz) and the switching losses are very small. The sinusoidal pulse width modulation SPWM requires a carrier frequency not less 20 times the system frequency so SHE approach is found to be superior compared with SPWM. Also, SHE technique shows significant reduction in THD as the number of levels increased. Results for the output voltages and currents along with their frequency spectrum are shown and compared with traditional SPWM.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Northern Technical University
  • Universiti Sains Malaysia
  • Prince Mohammad bin Fahd University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rakan Khalil AntarNorthern Technical University1
Abdallah Mohamed AbdullahNorthern Technical University1
Mohamed SalemUniversiti Sains Malaysia1
Dahaman IshakUniversiti Sains Malaysia1
Jawad Hasan AlkhateebPrince Mohammad bin Fahd University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Multilevel level single phase inverter implementation for reduced harmonic contents</dc:title>
	<dc:creator>Hussein, Taha Ahmed</dc:creator>
	<dc:subject xml:lang="en-US">Arduino, MLI, SHE, SPWM</dc:subject>
	<dc:description xml:lang="en-US">Selective harmonic elimination technique SHE is adopted in this work to reduce the harmonic contents in single phase cascaded multilevel inverter. The firing instants for the electronic switches MOSFETs in the inverter are calculated off line for five level to thirteen level inverter. An Arduino microcontroller is programmed to cope with different topologies of the multilevel inverter. The implemented multi-level (MLI) inverter results are compared with Simulink simulation program and are found very close to each other. SHE technique works at system frequency (50 Hz or 60 Hz) and the switching losses are very small. The sinusoidal pulse width modulation SPWM requires a carrier frequency not less 20 times the system frequency so SHE approach is found to be superior compared with SPWM. Also, SHE technique shows significant reduction in THD as the number of levels increased. Results for the output voltages and currents along with their frequency spectrum are shown and compared with traditional SPWM.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21032</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i1.pp314-324</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 1: March 2021; 314-324</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21032/13351</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Taha Ahmed Hussein</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>