Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Differential game theory with FPA optimization in multi-area power system

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 1 (2020) · hlm. 302–308

DOI
10.11591/ijpeds.v11.i1.pp302-308
ISSN
2722-256X, 2088-8694
Terbit
2020-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The distribution generation penetration increases due to the increased need of power. These penetration causes problem of frequency deviations. In this paper the in multi-area power system the combination of renewable energy resources is proposed. Here the area 1 & area 2 are thermal power plant. Hydro power generation plant is taken in area-3 & area-4. Renewable energy system is considered in area-5. Here the cyber security attack is taken as change in power in the entire area. This can make the power block out or wrong data entry. Here differential game theory-based problem formulation is done. The PI controller and differential game theory with flower pollination are compared for performance of fast response. The MATLAB 2017b is used for building the areas and algorithm

Jaringan kolaborasi para penulis

9 penulis · 12 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jawaharlal Nehru Technological University Anantapur
  • Jawaharlal Nehru Technological University, Hyderabad
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
D. Chandra SekharJawaharlal Nehru Technological University Anantapur1
P. V. V. Rama RaoAfiliasi tidak diketahui1
Subramanya Sarma SJawaharlal Nehru Technological University Anantapur1
V. GaneshJawaharlal Nehru Technological University Anantapur1
Manne Rama SubbammaAfiliasi tidak diketahui1
K. S. R. AnjaneyuluJawaharlal Nehru Technological University Anantapur1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Differential game theory with FPA optimization in multi-area power system</dc:title>
	<dc:creator>Khadarvali, S.</dc:creator>
	<dc:creator>Madhusudhan, V.</dc:creator>
	<dc:creator>Kiranmayi, R.</dc:creator>
	<dc:description xml:lang="en-US">The distribution generation penetration increases due to the increased need of power. These penetration causes problem of frequency deviations. In this paper the in multi-area power system the combination of renewable energy resources is proposed. Here the area 1 &amp;amp; area 2 are thermal power plant. Hydro power generation plant is taken in area-3 &amp;amp; area-4. Renewable energy system is considered in area-5. Here the cyber security attack is taken as change in power in the entire area. This can make the power block out or wrong data entry. Here differential game theory-based problem formulation is done. The PI controller and differential game theory with flower pollination are compared for performance of fast response. The MATLAB 2017b is used for building the areas and algorithm</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19942</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i1.pp302-308</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 1: March 2020; 302-308</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/19942/13059</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 S. Khadarvali, V. Madhusudhan, R. Kiranmayi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>