Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design of Optimal LLCL Filter with an Improved Control Strategy for Single Phase Grid Connected PV Inverter

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 1 (2018) · hlm. 114–125

DOI
10.11591/ijpeds.v9.i1.pp114-125
ISSN
2722-256X, 2088-8694
Terbit
2018-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The third order LLCL filter is gaining more attractive in grid connected PV inverter in terms of material cost saving than LCL filter. Several active and passive damping techniques prevail in mitigating the resonance problem for maintaining the grid power quality standards. In this paper an improved passive damping is examined with reduction of power loss for the LLCL filter. Particularly, it reduces the switching ripple much better than LCL filter, with a decrease in volume of the inductance. The filter design is also developed for the operation of stiff grid. Mathematical operations and transfer function are derived with frequency response for the accuracy of the filter design. In addition, comparative analysis of passive and improved passive damping control is proposed. The control strategy is improved with feedback linearization in order to avoid the glitches in inverter control and is verified with prototype grid connected PV inverter.

Jaringan kolaborasi para penulis

7 penulis · 9 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Vellore Institute of Technology University
  • Escola Superior Aberta do Brasil
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
S. ParamasivamEscola Superior Aberta do Brasil2
R. GovarthananVellore Institute of Technology University1
Ramesh PanduranganVellore Institute of Technology University1
Lakshman Naik PopavathVellore Institute of Technology University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of Optimal LLCL Filter with an Improved Control Strategy for Single Phase Grid Connected PV Inverter</dc:title>
	<dc:creator>Arulkumar, K.</dc:creator>
	<dc:creator>Vijayakumar, D.</dc:creator>
	<dc:creator>Palanisamy, K.</dc:creator>
	<dc:description xml:lang="en-US">The third order LLCL filter is gaining more attractive in grid connected PV inverter in terms of material cost saving than LCL filter. Several active and passive damping techniques prevail in mitigating the resonance problem for maintaining the grid power quality standards. In this paper an improved passive damping is examined with reduction of power loss for the LLCL filter. Particularly, it reduces the switching ripple much better than LCL filter, with a decrease in volume of the inductance. The filter design is also developed for the operation of stiff grid. Mathematical operations and transfer function are derived with frequency response for the accuracy of the filter design. In addition, comparative analysis of passive and improved passive damping control is proposed. The control strategy is improved with feedback linearization in order to avoid the glitches in inverter control and is verified with prototype grid connected PV inverter.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/10959</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i1.pp114-125</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 1: March 2018; 114-125</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/10959/11117</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 K. Arulkumar, D. Vijayakumar, K. Palanisamy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>